Planning & Design Meetings Draft of the Initial Study for the CEQA Mitigated Negative Declaration 10/3/2009 - MinutesPalo Alto High School Master Plan 1 ESA / 209002
Initial Study September 2009
PALO ALTO HIGH SCHOOL MASTER PLAN
Initial Study and Environmental Checklist Form California Environmental Quality Act (CEQA)
1. Project Title: Palo Alto High School Master Plan
2. Lead Agency Name and Address: Palo Alto Unified School District
25 Churchill Avenue, Building D
Palo Alto, CA 94306
3. Contact Person and Phone Number: Tom Hodges, Program Director Telephone:(650) 329-3972 E-Mail: thodges@pausd.org
4. Project Location: 50 Embarcadero Road
Palo Alto, CA 94301 5. Santa Clara County Assessor’s Parcel Numbers: 008-02-034
6. Project Sponsor’s Name and Address: Palo Alto Unified School District
25 Churchill Avenue, Building D
Palo Alto, CA 94306
7. General Plan Designation: School District Lands
8. Zoning: PF – Public Facilities
9. Description of Project: The proposed project includes construction of new buildings,
renovation of existing structures, and other site improvements as part of the Master
Plan for Palo Alto High School. See Project Description, below, for details of the
Master Plan.
10. Surrounding Land Uses and Setting: The project site is within an urban area in the
City of Palo Alto. Existing adjacent land uses include residential areas on the east and
southeast, Stanford University on the west, and a commercial/retail shopping center
on the north.
11. Other public agencies whose approval is required (e.g., permits, financing
approval, or participation agreement): During the Site Improvements, the project
may require an encroachment permit from the California Department of
Transportation (Caltrans) for utilities tie-in to El Camino Real (State Route 82) and
Initial Study
Palo Alto High School Master Plan 3 ESA / 209002
Initial Study September 2009
Project Description
Background
Palo Alto Unified School District (PAUSD or District) was founded in 1893. The District
includes the City of Palo Alto, Stanford University, and areas of Los Altos Hills, Palo
Alto Hills, and Portola Valley within its attendance area. See Figure 1 for attendance
boundaries. PAUSD consists of twelve elementary schools (grades K-5), three middle
schools (6-8), and two high schools (9-12). In addition, the District operates a pre-school,
Young Fives program, a self-supporting Adult School, the Hospital School at Stanford’s
Lucille Packard Children’s Hospital, and summer school. The District enrollment for the
2008/2009 school year was approximately 11,430 students.
Palo Alto High School (Paly), located at 50 Embarcadero Road in Palo Alto, has an
existing student capacity of 1,950. Enrollment at Paly has steadily increased over the last
ten years from 1,489 students in the 1998/1999 school year to 1,772 for the current
(2008/2009) school year. The school employs approximately 116 certified faculty and
administrative staff. The projected capacity of Paly at completion of proposed
improvements in 2018 is 2,300 students, an increase of approximately 23 percent.
Long Range Facilities Master Plan / Measure A
In January 2006, PAUSD staff presented to the Board of Education a School Site Status
Report that provided an assessment of the improvements made to District facilities during
the Building for Excellence Program and outlined the future needs of the PAUSD.1 The
Board authorized staff to prepare a 20-year facilities master plan that would identify
facilities needs that were not funded by the Building for Excellence Program and to
outline a growth strategy to accommodate projected increases in enrollment.
The Long Range Facilities Master Plan (LRFMP) is a conceptual document that was
presented to the Board in April 2007. The LRFMP includes an implementation plan for
capital improvements, planned maintenance, and equipment and furnishing needs over
the next twenty years. This document also incorporates current codes and principles from
the Collaborative for High Performance Schools (CHPS).2 These standards incorporate
the latest green building practices to reduce operating costs through sustainable and
energy efficient design, reduce environmental impacts, and increase building life, while
creating schools that are healthy and comfortable for students and staff.
1 "Building for Excellence" was a 1995 tax measure that funds upgrading school facilities and some technology
items, such as computers.
2 The Collaborative for High Performance Schools (CHPS) is the United States' first green building rating program
especially designed for K-12 schools. CHPS provides information and resources to schools in order to facilitate the
construction and operation of high performance institutions. A high performance school is energy and resource
efficient as well as healthy, comfortable, well lit, and containing the amenities for a quality education.
;
;
;
;
;
;;
;
;
;
;
;
;
;
;
;
;Palo Alto HS
Gunn HS
ARASTRADERORD
ALPINERDFOOTHILLEXPY
USHIGH
WAY101
JUNIPEROSERRABLVDSANDHILLRD
PAGEMILL
RDMIDDLEFIELDRD
ALMAST SAN ANTONIORD
EL
CAMINO
REAL
EMBARCADERORD
LOUISRD
EMEADOWDR
COWPERST
ECHARLESTONRD
OR EGON EXPY
COLORADO AVE
LOMAVERDEAVEUNIVERSITYAVEWILLOW RDOhlone
Hoover
Terman MS
JLS MS
Barron Park
Nixon
Hays
Palo Verde
Briones
Duveneck
Escondido
El Carmelo
Addison
I280
OAKCREEKDR
HANOVERST
LACRESTADRALTARD
MIRANDAAVE
JEEPTRL
EMEADOWCIR
FABIAN
WAYWELCHRDWALTERHAYSDR
COYOTEHILLRD
ESPERANZADR
EBAYSHORERD
HILLVIEW
AVE
USHIGHWAY101
WBAYSHORERD
PORTERDR
COUNTRYWAY
KENNETHDR
LASUENMAL
ALPINERD
PETERCOUTTSRD
ALEXISDR
ELENARD
PETERCOUTTSCIR CHIMALUSDR
JUNIPEROSERRABLVD
ARASTRADERORD
LOSTRANCOSWOODSRD MOONLN
DEERCREEKRD
ROBLELADERARD
HANSENWAY
SANDHILLRD
EDGERTONRD
LAURELGLENDR
VIA
VEN
TANA
BENLOMONDDR
CREEKSIDEDR
CHRISTOPHERSLN
IRISWAY
S FORK LN
VIAFELIZ
GERTHLN
DESOTODR
MEARSCT
STORYHILLLN
CHRISTINEDR
LOST
RANCO
SRD
TOLMANDR
NATOMARD
NFORKLNSTANFORDSHOPPINGCENTER OLDA
DOB
ERD
PURISSIMARDPAGEMILLRD
GERONARD
GOVERNORSAVE
ANACAPADRLIDDICOATCIR
LASUENST
FOOTHILLEXPY TANLANDDR
HOLLYOAKDR
SANTATERESAST
RAMONAST
MATADEROCREEKLN
BOWDOINST
SAMMCDONALDRD
ALMAST
CATHCARTWAY
CAMPUSDRE
ALLARDICEWAY MORRISDR
EMERSONST
AMARILLOAVEPITMANAVE
ASCENSIONDR SANANTONIORDVIACRESPI
MATADEROAVE
OLDPAGEMILLRD
SADDLEMOUNTAINDR
MIR
MIROU
DR
BRYANTST
DANAAVE
JOSINAAVELNL
LAPALOMARD
HILBARLN
PALMDR CRESCENTDR
ARBORETUMRD
LAGUNITADR OREGONAVE
MANUELAAVE
MAYFIELDAVE
SOUTHCT
ROOSEVELTCIR
STOCKFARMRD
HAMILTONAVE
SANTAANAST
JANICEWAY
BARBARADR
VISCAINORD
FOREST AVE
TRANSPORTSTCAMPUSDRWCAMPUSDR
WAVERLEYST
KIPLINGST
EDGEWOODDR
ARROYO
CTCOTTRELLWAY
GEORGIAAVE MON
TRO
SEAVE
ELCAJONWAY
URBANLN
NCALIFORNIAAVE
SUZANNEDR
MARSHALLDR
BYRDLN
PALOALTOAVE
PASEODELROBLE
CONCEPCIONRD
ADDISON
AVE
VISCAINOCT
THOMASDRJACKSONDR
CURTNERAVE
LUPINERD NORTHAMPTONDR
DUNCANPL
ELCAMINOREAL
COASTLANDDR
LAPARAAVE
OLMSTEDRD
FREMONTRD
ARIC LN HEATHERLN STFRANCISDR
NEWMAYFIELDLN
WCHARLESTONRD
CABRILLO
AVE PATRICIALN
MADDUXDR
ORMEST
SOUTHAMPTONDR
WELLSBURYWAY
AMHERSTCT
WELLESLEYST
VANAUKENCIR
FLORALESDR
WARRENWAY
MIDDLEFORKLN
LEANDERDR PRIMROSEWAY
SERRAST
PAULAVE
CEREZADRGUINDAST
LOUISRD
STFRANCISRD
LACRESTACT
ARGUELLOST
AYRSHIREFARMLN
NELSONRD
PANAMAST
OAKRD
MIDDLEFIELDRD
BICYCLEPATH
CREEKPARKDR
VERNONTER
STMICHAELDR
TASSOST
COLONIALLN
GALVEZST
PEARCEMITCHELLPL
SEQUOIALN
DONALDDRCAMBRIDGEAVE
WEBSTERST
NATHANW
AY
PINEHILLRD
CANARIO
WAY
ROBLEBLANCOCT
ELECTIONEERRD
ROBLE
RIDGE
RD TULIPLNLNB
STANFORDAVE
LAGUNAWAY
GREENWOOD AVE
BYRONST
WESTON DR
CO
RINAW
AY
ALTATIERRARD
BANDERADR
FOOTHILLLN
BRYSONAVE
VALPARAISOST
ALGERDR
ROSSRD
OAKHILLAVE
OLDTRACERD
HUBBARTTDR
MARGARITAAVE
ENCINAAVE
EMEADOWDR
BERRYHILLLN
WILTONAVECOWPERST
NEWELLRDCENTERDR
SANTAFEAVE
MEMORIALWAY
FERNANDOAVE
LABARRANCARD
MELODYLN
CLARADR
PARKBLVD
SEARSVILLERD
METROCIR
GOLFLN BLAKEWILBURDR
FRENCHMANSRDQUARRYRD
RHODADR
BLACKMOUNTAINRD
BONAIRSIDINGRD
OBERLINST
MAGNOLIADR CARLSON
CIR
PARKSIDEDRMIRADAAVE
SYCAMOREDR
KENDALLAVERUNNINGFARMLN SUTHERLANDDR
LIDDICOATDR
CAROLINALN
JARVISWAY
OLIVEAVE
CABALLOLN
FAIRMEDEAVE
HARVARDST
MOFFETTCIR
DINAHSCT
TENNESSEELN
WILDWOODLN
NINAPL WFRE
MON
TRD LOISLN
DARTMOUTHST
STANFORDST
PRINCETONST
LATHROPDR
LNW
AMHERSTST
COLUMBIAST
CORNELLST
THE
NDARAW
AY
SANTAYNEZST
MORENOAVE
MANUELACT
LUPINEAVE
ECHARLESTONRD
ARBUTUSAVE
HARKERAVE
OLDTRACELN ELYPL
RAIMUNDOWAY LOSROBLESAVE TORREYACT
WILLIAMSST
ECRESCENTDR
GROVEAVE
ROBBRD
MEDICALLN
SADDLECT
VENTURAAVEBOYCEAVEMARIPOSAAVE
ASHBYDR
FERNEAVE
CUMBRAVISTACT
STARRKINGCIR
REDWOODCIR
NATHANABBOTTWAY
ILIMAWAYFULTONST
VINEYARDLN
RADCLIFFELN
EMBARCADERORD
CROTHERSWAY
SALVATIERRAST
VERNIERPL
WESTWINDWAY
BAKERLNCLARKWAY
ALTOVERDELN
LINCOLNAVE
OREGONEXPYWCRESCENTDR
COMSTOCKCIRESCONDIDORD
RICHARDSONCTSUTTERAVE
ELCERRITORD ELCAMINOWAYJEFFERSONDR
CHANNINGAVE
SHERMANAVEPALORD
MORTONWAY
PASTEURDR
CEDROWAY
URSULALN
LAVIDAREAL
LASELVADR
RAMBOWDR
MARKTWAINST
OBRINELN
WRIGHTWAY
ALVARADOROW
ESTRALITAPL
CLEMOAVE
NEVADAAVE
ALESTERAVE
PONC
EDRPEPPERAVESCALIFORNIAAVECOLLEGEAVE
MANZANALN
2NDST
WILKIEWAY
COLORADOAVE
PIERSLN
OR
TEGACT
MATADEROCREEKCT MINORCACTKINGSLN
BIBBITS
DR
SEALEAVE DENNISDREVERETTAVE
VIAORTEGA
LAMBERTAVE
SHERIDANAVEGRANTAVE
SEMINOLEWAY
STELLINGDR LOMAVERDEAVE
CHURCHILLAVE TENNYSONAVE
KINGSLEYAVE
HAWTHORNEAVE HOMERAVE
SANTAMARIAAVE GARLANDDRLOSARBO
LES
AVE CHAUCERST
SANTARITAAVE
EDLEEAVEMELVILLEAVECELIADR
EVERETTCT
VOGUECT
CONSTANZOST
JORDANWAY
LELANDAVEKELLOGGAVE MARION AVEGREERRD
WELLSAVE
MIRANDAGREENST
ORTEGADR
HALEST
RINCONADAAVELOWELLAVECOLERIDGEAVEBRYANTCT
UNIVERSITYAVE
SANTATERESALN
COWELLLN
NELSONDR
PARADISEWAYSANJUDEAVE ENCINAGRANDEDR
BARRONAVEOXFORDAVEMADISONWAY
VIACERROGORDO
YUBALN
ESPLANADAWAY
IVYLN
FIFEAVE MARTIN AVE
WASHINGTONAVELYTTONAVE
MANDOLIDR
CAMPANADR
LADONNAAVE
MESACT
DAKEAVEJAMESRD
ANDELLCT
EVERGREENDR
BLACKWELDERCT MAYVIEWAVE
MILITARYWAY
BEAVERLN
WINGPL
WHITMANCT
ABELAVE
GIGLICTACACIAAVEBARNESCT
MESA AVE
RUTHELMAAVE
FAWNCREEKCT
MANUELA WAY STONELN
ROTHWAY
MUSEUMWAY
ROBLEALTOAVE
DOLORESST
MANU
ELLAR
DPORTAGEAVE
BIRCHHILLWAY MAYCT
MOCKINGBIRDLN CORKOAKWAY
CASTILLEJAAVE
FLOWERSLN
MATADEROCT
CORTEMADERALN
SANANTONIOWAY
SONOMA TER
MARIONWAY BLAIRCT
LATHROPPL
ELLSWORTHPL
MCKELLARLN
CASANUEVAPL
PRICECT
CALLEDELSOL
BAKERAVE
ASHST
BRETHARTEST
SOUTHWOODDR
HOSKINSCT
CO
OKSEY
LN
LANEBW
LANE8W
HIGHST
LANE7E
MITCHELLLN
SENECAST
SANJUANST
MAYBELLAVE
DAVIDAVE
MAPLEWOODAVE
ESTUDILLORD
MUMFORDPL
MCFARLANDCT
PAMPASLN
ESCOBITAAVELOMITADR
DAWNLN OHLONELN
DUDLEYLN TALISMAN CT
WHITSELLAVE
ARCADIAPL
BUCKEYELN
COWPERCT
LANEDE
CHABOTTER
LN56
LANE15E
LANEAW
LANE59E
LANEDW
RYANCT
THOBURNCT
TOWLEWAYSANCARLOSCTFIELDINGDR
VILLAREAL
STANFORDCT
MURDOCHDR
COUNTRYCLUBCT MADRONOAVE STERNAVE
WALNUTDR
ELCENTROST
AVALONCT
LN39
ILIMACT
WMEADOWDR
BRIARWOODWAY
LANE7W
SCOTTST
SANTACATALINAST
GILMANST
DOWNINGLN
LANEBE
KINGARTHURCT
MCGREGOR
WAY
STIRRUPWAY
DELS
ONCT VISTAAVE
QUILLENCT
PORTOLAAVE
ABBORETUM RD
PARKAVE
BALERIRANCHRD
ELCAPITANPL
CARILLOLNABRAMSCT
MURRAYWAY
SANDRAPL
HOPKINS AVE
PARKINSON AVE
SHASTADRROSSCTCARDINALWAY
ARROWHEADWAYPALMST
ALEJANDRODR
VIAVENTANAWAYELBRIDGEWAY
HU
TCHINSO
NAVE ERSTWILDCT
VILLAVISTA
OLDTRACECT
COMMUNITYLN
DURAND
WAY
JENKINSCT
LINDERODR
WHITCLEMDR
MAUREENAVEWINTERGREENWAYSWAINWAY
SIMONLN
BERRYHILLCT
BIRCHST
COWDENPL
HORSESHOELN
LOSPALOSAVEMACLANEST
SANFRANCISCOCT
CHARLESMARXWAY
LN33
MOSHERWAY
DIABLOCTTIOGACTHULMECTPOEST
CAMINOMEDIOLN CHESTNUTAVEJACARANDALNMAPLEST
THAINWAY
GAILENAVE
YALEST
LAURELLN
LAURALN
GREENMEADOWWAY
HA
RRIET
ST
STAUNTONCT
LOSALONDRASCT
COLORADOPL
SUNRISEFARMRD
ADONNACT
TIPPAWINGOAVE
ASHTONAVE
ELDORADOAVE
ELCARMELOAVE
STCLAIREDR
AVILACT
PALO HILLS DR
SPRINGHILL DR AMESAVE
STOCKTONPL
LUNDYLN
MOANACT ELVERANOAVE
EGREENWICHPL
RUTHVENAVE
ROSEWOODDR
STMICHAELCT
LAWRENCELN
ELSINOREDR
DRISCOLLPLVIAPALOUMARLOWEST
DRISCOLLCTLOMITACT
ROBLEVENENOLNDUENAST RHODESDR
SANANTONIOAVESIERRACT
AMARANTAAVEORINDAST
CLIFTONCT
LNC SIMKINSCT
RAMOSWAYROBLEDR
MACKAYDR CHRISTOPHERCT
THREE FORKS LN
INTERDALEWAY
WAVERLEYOAKS
POMONAAVE
KEATSCT
TALISMANDRTOYONPLMANZANITAAVE
HIGGINSPLPORTALPLLN20
PIERSCT
SHADYOAKSCT
LUCE
ROLN ISLANDDR
SCRIPPSAVE
VENTURACT
RANDERSCT
LUCASLN
CARMELDR
IRVENCT
HA
MILT
ONCT
ELESCARPADO WILS
ONST
VIACORITAWAY ENSIGNWAY
GLENBROOKDRSOLANADR
VERDOSADR
VISCAINOPL CERRITOWAY
VIAARLINERD
CARRINGTONCIR
LNA
KELLYWAY
LAYNECT
BURNHAMWAY
FLORENCEST
VARIANWAY
CONEJOCT
VIAPUEBLO
YNIGOWAY
JACOBSCT
TRIPOLICT
LANE13E
CE
DAR
STFORESTCT
SH
ARO
NCT
DIXONPL
DRIFTWOODDRLANE30E
LAGUNAAVE
MACKALLWAY
AGNESWAY
NALTALNVALDEZPL DAVENPORTWAY
WEBSTERCT DAVIDCT
WATSONCT
SANANTONIOCT
GASPARCT
LINDALN
HARVARD
CT
SANDALWOODCT
JORDANPL
SHAUNALN NEWBERRYCTALLENCT
BELLVIEWDR
TEVIS PL LOUISACT
WRIGHTPL
MANCHESTERCT
WALLISCT
CHARLESTONCT
PASEODELROBLECT KIRBYPL
SAN
RAF
AEL
PL
CORTEZLN
VICTORIAPL
STOLMANLNTHECIR
FAIRFIELDCT
ANTONCT
GENEVIEVECT
ELMDALECT
LAMATAWAY
REGENT PL KENT PL
SOMERSET PL
WINDSORCT
SAMUELLN
PENACT
CORINA
CT
RINCONCIR
DARLINGTONCTWILKIECTCORONADOAVE
CROSBYCT LEGHORN ST
FERNECT
NTOLMANLN
AMESCT
TRA
CYCT BARCLAYCTALVARADOCTGARYCTDYMONDCT
MARIRAPL
ELSINORECT
MADELINECT
JULIECT
ANACAPACT
GROVELN
NEWELLPL
TIMLOTTLN
HEMLOCKCT
GAILENLN
MARTINSENCTWELLSBURYCT
SUZANNECTPALOALTOSQ DULUTH CIR
MEADOWCREEKCT
NATHANCTSTELLINGCT
YALE CT
GREENMANOR
LOSPALOSCIR
LORABELLELN
WHITCLEMCT
GROVECT
LUMASVERDESAVE
FRENCHMANSRD
PARADISECT
FELTLAKEHigh School Attendance Areas
Palo Alto Unified School District
I280
Lapkoff & Gobalet Demographic Research, Inc. 6/2007www.Demographers.com
HAMILTONAVE
Richard W. LymanGraduate Residencesplus Santa Teresa Lanehomes assigned to Palo Alto HS
Palo Alto High School Master Plan . 209002
Figure 1
High School Attendance Boundaries,
Palo Alto Unified School District
SOURCE: Lapkoff & Gobalet Demographic Research, Inc.
Initial Study
Palo Alto High School Master Plan 5 ESA / 209002
Initial Study September 2009
On June 3, 2008, voters in the District approved a $378 million bond issue, Measure A
(Palo Alto School Modernization and Expansion Bond of 2008), that would provide
funding to implement the LRFMP.
The proposed project, the Palo Alto High School Master Plan (Master Plan) is a
component of the LRFMP. PAUSD, serving as Lead Agency under the California
Environmental Quality Act (CEQA), is completing the required environmental review of
the Master Plan pursuant to CEQA, prior to approval of the plan. In accordance with the
CEQA Guidelines, PAUSD has prepared an Initial Study to determine the potential
environmental consequences of adoption and implementation of the proposed Master
Plan. This Initial Study provides the necessary information to inform PAUSD, other
responsible agencies, and the public of the nature of the project and its potential effect on
the environment.
Project Location and Existing Site Characteristics
Paly was originally constructed in 1918 on an approximately 44-acre site (the project
site) southeast of the intersection of State Route 82 and Embarcadero Road (see Figure
2). The campus is owned and occupied by the PAUSD, but the site has a reversionary
clause to Stanford University on 26 acres. Adjacent land uses include residential areas to
the east and southeast, Stanford University to the west, and the Town and Country
Village shopping center to the north.
The Paly campus consists of 17 buildings constructed between 1918 and 2004. The
original construction in 1918 included the Administration and Classroom Building and
the Auditorium Building (also known as the “Haymarket Theater”). Much of the original
administration/classroom building was demolished in 1972, leaving the two-story portion
referred to as the “Tower Building.” In 1928, the original Boys’ Gymnasium was
constructed; it was expanded in 1946 to provide locker and shower facilities and staff
offices. The construction of the Industrial Arts Building was completed in 1945 and
expanded to include an electronics classroom in 1955. In 1960, the Science Classroom
Building was constructed. The addition of the Girls’ Gymnasium and the swimming pool
were completed in 1969. In 1968, the Administration Building, Auditorium, and the
Boys’ Gymnasium were extensively renovated as part of seismic retrofitting.
The majority of the other buildings on campus were constructed in the early 1970s. These
include the following structures: Fine and Performing Arts Building, English Building,
Lecture Center, Social Studies Building, Foreign Language Building, Math and Science
Technology Building, and Resource Materials Center. These are single-story rectangular
or square buildings with hipped tiled roofs and wood siding. The roof structure of these
buildings extends over a walkway, which surrounds the buildings allowing covered
exterior access to most of the classrooms, or exterior access to the interior classrooms.
During the Building for Excellence program the majority of these buildings were
modernized with the exception of the Library Building and the Fine Arts Building.
82
PAGE MILL RDARASTRADERO RDEL
C
A
M
I
N
O
R
E
A
L
FOO
TH
IL
L SAN ANTOPAGE MILL RDCHAR
L
E
S
T
O
N
R
D
MI
D
D
L
E
F
I
E
L
D
RD
AL
M
A
S
T
EMBARCA
D
E
R
O
R
DUNIVERSITY AVWILLOW RDPALO ALTO
MOU
VI
MOU
VI
EAST
PALO ALTO
Stanford
SAN FRANCISCO BAY
PROJECT
LOCATION
101
Palo Alto High School Master Plan . 209002
Figure 2
Project Location
SOURCE: ESA
01
Mile
Pacific Ocean
NOVATO
SANRAFAEL
MOUNTAINVIEW
SAN
JOSE
FREMONT
HAYWARD
SANRAMON
WALNUT
CREEK
CONCORD
SANTA ROSA NAPA
FAIRFIELD
ALAMEDASANFRANCISCO
DALYCITY
BERKELEY
VALLEJO
VACAVILLE
REDWOOD
CITY PALO
ALTO
SANMATEO
OAKLAND
PROJECT
SITE
RICHMOND
Initial Study
Palo Alto High School Master Plan 7 ESA / 209002
Initial Study September 2009
Other additions to the campus include a Student Activities Center and Woodshop in 1975
and a new Science Building in 2004. In 1998, following the Loma Prieta Earthquake, the
Campanile of the Tower Building was separated from the structure and strengthened. The
campus also includes approximately 17 relocatable classrooms.
Recreational facilities are located primarily on the southern portion of the campus and
include a football field and track, baseball and softball diamonds, swimming pool,
athletic field, seven tennis courts, and four basketball courts.
The PAUSD Administrative Office and Corporation Yard are also located on the project
site. The Corporation Yard is located just north of the football field and the District
Office occupies the southwestern corner of the campus. The District Office is a single-
story structure, built in 1955 and expanded in 1960, and has its own parking area that is
separate from the high school.
Parking areas surround the school buildings on the northern perimeter of campus off of
Embarcadero Road. Additional parking is located on the south-central area of the campus
between the football field and baseball/softball diamonds with access via Churchill
Avenue. Approximately 555 parking spaces are available, not including 100 spaces at the
District Office.
The campus is served by three access points: Embarcadero Road on the north, El Camino
Real on the west, and Churchill Avenue on the south. The Caltrain railroad track is
located on the east side of campus, which prevents access to the campus from this
direction.
Proposed Improvements
The proposed project features construction of new buildings and other structures;
renovation of some existing buildings; utility and infrastructure improvements; open
space and landscaping enhancements; and pedestrian/bicycle/vehicular circulation
improvements.
Specific components of the proposed Master Plan improvements are summarized in
Table 1, below. Construction of individual projects on the campus would occur in groups
or phases over the time period of the Master Plan, with buildout targeted for 2017.
Specific projects within each project group would be constructed over the same general
time period, but not necessarily simultaneously. Locations of proposed projects are
indicated on Figures 3 through 8. Improvements to the athletic field adjacent to El
Camino Real (a non-Measure A project) is underway and scheduled to be completed in
January 2010.
Renovations of existing buildings may include, but are not limited to, upgrades to
electrical, communication, water and wastewater systems; replacement or modification of
heating and cooling systems; lighting improvements; replacement of roofs; upgrade or
addition of restrooms; improvement to comply with the Americans with Disabilities Act
Initial Study
Palo Alto High School Master Plan 8 ESA / 209002
Initial Study September 2009
(ADA) and California Title 24 requirements; and exterior improvements to walls, doors,
and windows.
Initial Study
Palo Alto High School Master Plan 9 ESA / 209002
Initial Study September 2009
TABLE 1
MASTER PLAN PROJECT LIST
Phase Project Description Schedule/Timeline
Group 1 1a: Football Stadium
Bleachers Replace existing bleachers Summer 2010
1b: Multi-Use Fields Replace existing baseball and softball fields and
facilities May 2010 – Feb 2011
Group 2 2a: Classroom Building New two-story, 27-classroom building 2011 – 2012
2b: Media Arts Center New building for media arts
2c: Utility & Infrastructure Miscellaneous utility improvements, including
drainage and Central Plant
Group 3 3a: Theater New 600-seat theater 2012 – 2014
3b: Theater Parking Reconfiguration of parking area
3c: Library Renovation of existing library
3d: Lecture Hall (Building
300A) Conversion of building into 150-seat lecture hall
3e: Weight Room / Fitness
Center
New building to connect existing gym to future
2nd gym
Group 4 4a: Career Tech Building New classroom building to replace Building 900 2014 – 2016
4b: Buildings 100, 300 &
700 Renovation of existing buildings
4c: Tower Admin. Bldg-
Phase 1
Renovation of existing building, including
accessibility
4d: Science Building Convert existing office space into science lab
Group 5 5a: Tower Admin. Bldg-
Phase 2 Renovation of existing building To be determined
5b: Haymarket Theater Renovation of existing building
5c: Gymnasium New gymnasium to replace existing small gym
5d: Gymnasium (Existing) Renovation of existing large gym
Group 6 6a: Student Center Renovation of existing building To be determined
6b: Quad Upgrade and enhance existing quad
6c: Utility & Infrastructure Miscellaneous building interior improvements
6d: Embarcadero / El
Camino Access & Parking Reconfiguration of access and parking areas
6e: Churchill Ave. Access
& Parking Reconfiguration of access and parking areas
6f: Site Improvements Miscellaneous landscaping and pedestrian
improvements
SOURCE: PAUSD, 2009
Palo Alto High School Master Plan . 209002Figure 3Palo Alto High School Master Plan, Group 1 ProjectsSOURCE: Deems Lewis McKinley
Palo Alto High School Master Plan . 209002Figure 4Palo Alto High School Master Plan, Group 2 ProjectsSOURCE: Deems Lewis McKinley
Palo Alto High School Master Plan . 209002Figure 5Palo Alto High School Master Plan, Group 3 ProjectsSOURCE: Deems Lewis McKinley
Palo Alto High School Master Plan . 209002Figure 6Palo Alto High School Master Plan, Group 4 ProjectsSOURCE: Deems Lewis McKinley
Palo Alto High School Master Plan . 209002Figure 7Palo Alto High School Master Plan, Group 5 ProjectsSOURCE: Deems Lewis McKinley
Palo Alto High School Master Plan . 209002Figure 8Palo Alto High School Master Plan, Group 6 ProjectsSOURCE: Deems Lewis McKinley
Initial Study
Palo Alto High School Master Plan 16 ESA / 209002
Initial Study September 2009
Group 1
Group 1 projects focus on improvements to athletic fields on the southern portion of the
campus. Bleachers on the home side (west) of the football stadium would be replaced
with a new approximately 1,400-seat bleacher section. A new handicapped lift and press
box would also be included in this project. The multi-use field adjacent to the District
Office would be redesigned and upgraded with new baseball/softball dugouts, batting
cages, and scoreboards.
Group 2
Two new buildings would be constructed during this phase: a two-story, 27-room
Classroom Building and a two-story Media Arts Center. The Classroom Building would
include additional space for offices, conference rooms, and restrooms. Nine relocatable
classrooms would be moved to the Quad and also adjacent to the pool to make room for
the new Classroom Building. Other relocatables currently located where the Media Arts
Center is proposed would be removed upon completion of the Classroom Building. The
remaining relocatables would be removed at buildout of this phase. Other improvements
during Group 2 would involve various infrastructure and utilities upgrades such as
drainage and central plant facilities.
Group 3
A new 600-seat theater with support facilities is proposed under Group 3; the theater
would be located just north of Building 100 and adjacent to Embarcadero Road. This site
is currently used for parking; therefore, construction of the theater would necessitate
alterations to the parking lot and a new alignment from Embarcadero Road. Other
improvements scheduled during this phase include renovation of the existing Library
with a new front entrance and interior upgrades and conversion of the existing Building
300A into a 150-seat lecture hall. Another new building, a Weight Room/Fitness Center
would be constructed during Group 3. This structure would connect the existing
Gymnasium to a proposed future gym (proposed under Group 5).
Group 4 (Unfunded)3
The existing Building 900 would be demolished as part of Group 4 projects. This
building would be replaced with a new Career Tech Building featuring high bay flexible
space, home economics, robotics, auto shop, classrooms, and will centralize custodial
space. Three existing buildings would be renovated under this phase (Buildings 100, 300,
and 700) to accommodate special education, world languages, and English. Renovations
to the Tower Building would also occur, and would likely include installation of an
elevator, upgraded restrooms, new windows, and repair of the building’s heating system.
In addition, office space in the existing Science Building would be converted into a new
science lab.
3 Design of specific projects listed in Groups 4, 5 and 6 is currently unfunded.
Initial Study
Palo Alto High School Master Plan 17 ESA / 209002
Initial Study September 2009
Group 5 (Unfunded)
Additional improvements to the Tower Building would continue during this phase.
Proposed upgrades include seismic retrofit as well as new space for offices and
conference rooms. The Haymarket Theater would also be renovated as a part of Group 5
improvements, and would include seismic retrofitting and accessibility improvements.
One new building is proposed for construction, consisting of a new gymnasium to replace
the existing small gym. This new gym would become Paly’s primary competition facility
with a bleacher capacity of approximately 1,800 to 2,000; the new gymnasium would
also include offices and team rooms. The existing gym would be upgraded with
accessibility improvements and would also be used as a secondary competition facility.
Group 6 (Unfunded)
The last phase would feature expansion of the Student Center and would include a stage
for large gatherings and other events. The adjacent Quad would be enhanced to create an
improved pedestrian environment with new landscaping, furnishings, and other features.
Access to the campus from both Embarcadero Road and Churchill Avenue would be
improved as a part of Group 6 improvements. Improvements would reconfigure parking
areas to maximize available space and redesign bicycle and pedestrian pathways.
Additional changes under Group 6 would include other landscape upgrades and
modernization of existing buildings that were not improved during other phases of the
Master Plan.
Sources
California Department of Education, DataQuest, http://dq.cde.ca.gov/dataquest, accessed
June 24, 2009.
Palo Alto Unified School District (PAUSD), www.pausd.org, accessed June 2009.
PAUSD, Palo Alto High School Master Plan, 2009.
Initial Study
Palo Alto High School Master Plan 18 ESA / 209002
Initial Study September 2009
Environmental Impacts
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
1. Aesthetics
Would the project:
a) Have a substantial adverse effect on a scenic vista?
b) Substantially damage scenic resources, including,
but not limited to, trees, rock outcroppings, and
historic buildings within a state scenic highway?
c) Substantially degrade the existing visual character or
quality of the site and its surroundings?
d) Create a new source of substantial light or glare
which would adversely affect day or nighttime views
in the area?
Discussion
a-c) Less than Significant. Paly is located on the block bounded by Embarcadero Road
to the north, El Camino Real to the west, Churchill Avenue to the south, and Alma
Street / Caltrain railroad tracks to the east. None of these roadways have been
designated as or are considered eligible to be a state scenic highway, nor is the project
site visible from a state scenic highway (Caltrans, 2009). However, Embarcadero
Road is considered to be a scenic route by the City of Palo Alto and the entire length
of El Camino Real between San Diego and San Francisco, including the portion
through Palo Alto, is considered a State Historic Landmark (City of Palo Alto, 2007).
In addition, while not formally designated as historic resources, the Tower Building
(administrative offices) and the Haymarket Theater are considered historic buildings
for the purpose of this CEQA analysis (see Checklist Item 5, Cultural Resources).
The perimeter of Palo Alto High School’s campus is heavily lined by mature trees.
School buildings are mostly concentrated toward the middle of the site while ball
fields and parking lots dominate the periphery. Like most academic campuses,
buildings on Paly’s campus vary in style, massing, and height—generally ranging
from between one and two stories—but they are united by a common color scheme
that links most of the buildings and consists of beige stucco siding and red tile
roofs. However, due to the number of trees that line the campus along El Camino
Real and Embarcadero Road and substantial building setbacks from the surrounding
roadways, views of the buildings on campus are intermittent or obscured.
Currently, the closest buildings to Embarcadero Road on the campus are set back
approximately 185 feet from the roadway. The buildings along the Embarcadero
frontage consist of relocatable classrooms and permanent classroom buildings. The
relocatable classrooms are small mobile units with flat roofs and brown exteriors
(see Figures 9 through 11 for existing views of the campus). These buildings are
Initial Study
Palo Alto High School Master Plan 19 ESA / 209002
Initial Study September 2009
not prominently visible from Embarcadero given the minimal massing and muted
color of the structures and due to
Palo Alto High School Master Plan . 209002
Figure 9
Existing Views of Palo Alto High School Campus
SOURCE: ESA
Relocatable and permanent classroom buildings along Embarcadero Road
View of Tower Building and Haymarket Theater from Embarcadero looking south
Palo Alto High School Master Plan . 209002
Figure 10
Existing Views of Palo Alto High School Campus
SOURCE: ESA
View of campus from Churchill Avenue and El Camino Real looking north
View of Tower Building from El Camino Real looking east
Palo Alto High School Master Plan . 209002
Figure 11
Existing Views of Palo Alto High School Campus
SOURCE: ESA
View of campus from corner of Embarcadero Road and El Camino Real looking southeast
View of campus from corner of Embarcadero Road and El Camino Real looking east
Initial Study
Palo Alto High School Master Plan 23 ESA / 209002
Initial Study September 2009
the trees that are located between the structures and the road. The permanent
classroom buildings consist of one-story structures with reddish-brown hipped
gable roofs. These buildings are also painted brown and are surrounded by
colonnades with off-white columns. While two of these permanent classroom
buildings are visible from Embarcadero Road, they also maintain a relatively low
profile due to modest massing and use of the muted color scheme.
The Tower Building and Haymarket Theater are the most prominent visual features
of the campus. The two-story Tower Building and Haymarket Theater exteriors are
of the Spanish Colonial Revival style with red-tiled gabled roofs and beige stucco
siding. The buildings contain various architectural embellishments including
rounded-arched doorways and windows, and terra cotta arches on the facades. The
bell tower on the Tower Building is visible from multiple viewpoints surrounding
the campus. The buildings are set back considerably from the roadways. Haymarket
Theater faces Embarcadero, but is setback approximately 400 feet. Views of
Haymarket Theater from Embarcadero are intermittent due to this setback and the
intervening trees. The Theater is not visible from El Camino Real because it sits
behind the Tower Building. However, the Tower Building, which faces El Camino
Real and is setback approximately 185 feet from the road, is highly visible from
both El Camino Real and Embarcadero and serves as a defining feature of the
campus.
Other components of the campus that front El Camino Real include a multi-use
field (El Camino Field, which is currently under construction and scheduled for
completion by November 2010), tennis courts, and the district offices. The district
office building is located at the corner of El Camino Real and Churchill Avenue.
These buildings are fairly nondescript, single-story structures with flat roofs and
beige stucco siding. They are only intermittently visible from the adjacent roadways
due to the trees along the perimeter of the campus. Views of the campus from
Churchill Avenue are dominated by sports fields in the foreground with one- and
two-story buildings in the background.
Under the proposed Master Plan, there would be several new buildings constructed
on Paly’s campus. In keeping with the existing development pattern, new buildings
would be concentrated toward the center of the campus with deep setbacks from the
roadways. Specifically, a two-story Media Arts Center and a 600-seat theater would
be constructed that would likely be visible from Embarcadero Road. The Media
Arts Center would replace the group of single-story, small-scale relocatable
classrooms that are located in the northern portion of the campus with a two-story
structure. The theater would introduce a new two-story structure on a portion of the
site that is currently undeveloped (see Figures 3 through 8 in the Project
Description). Both of these buildings would be setback from Embarcadero by at
least 70 feet and would be designed in a manner that would be compatible with the
current architectural styles of the campus.
Initial Study
Palo Alto High School Master Plan 24 ESA / 209002
Initial Study September 2009
In addition, the student center would include a one-story addition, and an existing
girls’ gymnasium would be replaced by a new gymnasium that could potentially be
visible from El Camino Real. However, the student center addition would sit behind
El Camino Field and would be set back approximately 285 feet from El Camino
Real. The new gymnasium, which would be a two-story structure, would be located
behind the tennis courts and would be set back approximately 245 feet from El
Camino Real. Again, these buildings would be constructed in a style that would
complement the rest of the buildings on campus.
The remaining improvements that would occur under the Master Plan would be
minimally visible from public viewpoints. Except for the replacement of the
bleachers at the football field, there would be no new development on campus near
Churchill Avenue. Landscaping changes, including the removal of some of the trees
located on campus, would occur under the Master Plan and could result in visual
changes to the campus (see Section 4, Biological Resources). However, the trees
lining the campus would remain largely intact and views of the high school would
continue to be partially obscured by the mature perimeter trees.
Overall, the improvements that would occur under the Master Plan would result in
minimal visual change along El Camino Real or Embarcadero Road. In addition,
views of the campus from viewpoints along El Camino Real or Embarcadero would
not be adversely affected. Views of the Tower Building from El Camino Real or of
the Tower Building or Haymarket Theater from Embarcadero would not be blocked
by any new development and would not be affected by changes that would occur
under the Master Plan. As noted above, new development would be designed in
compatible styles with the existing campus architecture. Thus, impacts of the
Master Plan related to scenic resources (including scenic highways) or the visual
character of the site and its surrounding would be less than significant.
d) Less than Significant. New buildings developed under the Master Plan would include
fixed exterior lighting attached to the building in order to promote safety. The campus is
located in an urban environment that has existing sources of light and glare associated with
nearby land uses. Adjacent homes to the south of the campus cast light from windows or
from outdoor security lighting. Commercial uses to the north cast light from signage,
parking lots and buildings. Stanford University, which is west of Paly, occasionally casts
light from the ball fields that are located along El Camino Real. In addition, local roadways
surrounding the high school provide street lighting and are also sources of light and glare.
Ambient light generated by buildings that could be developed or improved under the
Master Plan would be minimized on surrounding uses due to screening nature of the trees.
Lighting on proposed buildings would be focused so as to illuminate a specific area and
avoid spillover onto adjacent properties, particularly residential uses, to the extent possible.
Overall, the project would result in less than significant light or glare impacts.
Initial Study
Palo Alto High School Master Plan 25 ESA / 209002
Initial Study September 2009
Sources
City of Palo Alto, Palo Alto Comprehensive Plan, Land Use Element, adopted July 17, 2007.
California Department of Transportation (Caltrans), California Scenic Highway Mapping System website, http://www.dot.ca.gov/hq/LandArch/scenic_highways/index.htm, accessed July 21, 2009.
Initial Study
Palo Alto High School Master Plan 26 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
2. Agriculture Resources
In determining whether impacts to agricultural resources are significant environmental effects, lead agencies may
refer to the California Agricultural Land Evaluation and Site Assessment Model (1997) prepared by the California
Department of Conservation as an optional model to use in assessing impacts on agriculture and farmland.
Would the project:
a) Convert Prime Farmland, Unique Farmland, or
Farmland of Statewide Importance (Farmland), as
shown on the maps prepared pursuant to the
Farmland Mapping and Monitoring Program of the
California Resources Agency, to non-agricultural
use?
b) Conflict with existing zoning for agricultural use, or a
Williamson Act contract?
c) Involve other changes in the existing environment
which, due to their location or nature, could result in
conversion of Farmland, to non-agricultural use?
Discussion
a–c) No Impact. The project site is not located on or near any agricultural land, nor is
the site zoned for agricultural uses. The project site, as with the majority of
developed land in the City of Palo Alto, is designated as Urban and Built-Up Land
by the California Department of Conservation (Department of Conservation, 2007).
Therefore, the proposed project would not convert farmland to non-agricultural use
and would have no effect on farmland or any property subject to a Williamson Act
contract.
Sources
California Department of Conservation, Santa Clara County Important Farmland Map
2006, August 2007.
Initial Study
Palo Alto High School Master Plan 27 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
3. Air Quality
Where available, the significance criteria established by the applicable air quality management or air pollution control
district may be relied upon to make the following determinations. Would the project:
a) Conflict with or obstruct implementation of the
applicable air quality plan?
b) Violate any air quality standard or contribute
substantially to an existing or projected air quality
violation?
c) Result in a cumulatively considerable net increase of
any criteria pollutant for which the project region is
non-attainment under an applicable federal or state
ambient air quality standard (including releasing
emissions which exceed quantitative thresholds for
ozone precursors)?
d) Expose sensitive receptors to substantial pollutant
concentrations?
e) Frequently create objectionable odors affecting a
substantial number of people?
f) Conflict with the state goal of reducing greenhouse
gas emissions in California to 1990 levels by 2020,
as set forth by the timetable established in AB 32,
California Global Warming Solutions Act of 2006?
Discussion
a) Less Than Significant. The project site is located in the City of Palo Alto, within
the San Francisco Bay Area Air Basin (Bay Area). The Bay Area experiences
occasional violations of ozone and particulate matter (PM-10 and PM-2.5)
standards. Air Quality standards and regulations are enforced in the Bay Area Air
Basin by the Bay Area Air Quality Management District (BAAQMD).
When a project is proposed in a city with a general plan that is consistent with the
most recently adopted Clean Air Plan and if the project is consistent with the land
use designation of the general plan, then the project is considered consistent with
applicable air quality plans and policies.
As discussed in Checklist Item 9 Land Use and Planning, in this Initial Study, the
campus improvements and educational uses proposed as part of the project would
not substantially conflict with the goals and policies in the City of Palo Alto
Comprehensive Plan. Moreover, although not bound by local land use ordinances,
project components proposed by the PAUSD would nonetheless be consistent with
the land use designation and zoning for the campus.
The applicable Clean Air Plan (CAP) is the Bay Area 2005 Ozone Strategy. The
City’s General Plan is consistent with the CAP because data and projections from
the General Plan are incorporated into the CAP. The project, therefore, is consistent
Initial Study
Palo Alto High School Master Plan 28 ESA / 209002
Initial Study September 2009
with the plan. This is a less-than-significant impact because the project would not
conflict with the region’s air quality management plan.
b, c) Less Than Significant with Mitigation.
Construction Emissions
This analysis evaluates the effect of the site grading and the construction of Master
Plan improvements on the local and regional air quality. Development of this
project could affect local pollutant concentrations in two ways. First, during
construction, the project would affect local particulate concentrations by generating
dust. Over the long-term, the project might result in a slight increase in emissions
due to new motor vehicle trips associated with accommodation of a larger student
population.
Activities such as grading and excavation would generate substantial amounts of
dust (including PM-10) from “fugitive” sources, such as proposed earthmoving
activities to improve athletic fields and to excavate foundations; and vehicle travel
over unpaved surfaces, and lesser amounts of other criteria pollutants from the
operation of heavy equipment construction machinery (primarily diesel operated)
and construction worker automobile trips (primarily gasoline operated).
Construction-related dust emissions would vary from day to day, depending on the
level and type of activity, silt content of the soil, and the weather. Construction
activities may result in significant quantities of dust, and as a result, local visibility
and PM-10 concentrations may be adversely affected on a temporary basis during
the construction period. In addition, larger dust particles would settle out of the air
close to the construction site resulting in a potential soiling nuisance for adjacent
uses.
For the evaluation of construction-phase impacts, BAAQMD does not require a
detailed quantification of construction emissions. Instead, it recommends that
evaluation of the significance of impacts be based on a consideration of the control
measures to be implemented (BAAQMD, 1999). Generally, if appropriate measures
are implemented to reduce fugitive dust, then the residual impact can be presumed
to be less than significant. Without these measures, the impact is generally
considered to be significant, particularly if sensitive land uses (e.g., residential or
scholastic) are located in the project vicinity.
The Master Plan improvements that would require the greatest degree of grading
and earthwork would be the Group 1 improvements to the athletic fields on the
southern portion of the campus. Other project elements would disturb much smaller
areas of earth and have fewer construction impacts to localized PM-10 and PM-2.5
concentrations. The multi-use field at the southern end of campus is approximately
4.8 acres. Because construction grading would generate localized increased
concentrations of PM-10 and PM-2.5 in an area designated as non-attainment for
Initial Study
Palo Alto High School Master Plan 29 ESA / 209002
Initial Study September 2009
these pollutants, without appropriate dust mitigation, the impact would be
significant.
Mitigation Measure AIR-1: During future construction, PAUSD shall
require the construction contractor(s) to implement BAAQMD’s “basic” and
“enhanced” dust control procedures required for the multi-use field at the
southern end of campus which is greater than four acres in area. These
procedures would be required in addition to the “basic” dust control program,
which is required for all construction sites and which would mitigate the
potential impact to a less than significant level.
Elements of the “basic” and “enhanced” dust control program for project
components that disturb more than four acres shall include, but not necessarily
be limited to the following:
Basic Control Measures
• Water all active construction areas at least twice daily. Watering should
be sufficient to prevent airborne dust from leaving the site. Increased
watering frequency may be necessary whenever wind speeds exceed 15
miles per hour. Reclaimed water should be used whenever possible.
• Cover all trucks hauling soil, sand, and other loose materials or require
all trucks to maintain at least two feet of freeboard (i.e., the minimum
required space between the top of the load and the top of the trailer).
• Pave, apply water three times daily, or apply (non-toxic) soil stabilizers
on all unpaved access roads, parking areas and staging areas at
construction sites.
• Sweep streets (with water sweepers using reclaimed water if possible) at
the end of each day if visible soil material is carried onto adjacent paved
roads.
• Sweep streets daily (with water sweepers) if visible soil material is
carried onto adjacent public streets.
Enhanced Control Measures
• Hydroseed or apply (non-toxic) soil stabilizers to inactive construction
areas (previously graded areas inactive for ten days or more).
• Enclose, cover, water twice daily or apply (non-toxic) soil binders to
exposed stockpiles (dirt, sand, etc.).
• Limit traffic speeds on unpaved roads to 15 miles per hour (mph).
• Replant vegetation in disturbed areas as quickly as possible.
Initial Study
Palo Alto High School Master Plan 30 ESA / 209002
Initial Study September 2009
With implementation of these measures, project construction would not be expected
to violate any air quality standard or contribute to an existing or projected air
quality violation in the project vicinity.
Operational Emissions
Construction activities would also result in the emission of other criteria pollutants
from equipment exhaust, construction-related vehicular activity and construction
worker automobile trips. Emission levels for construction activities would vary
depending on the number and type of equipment, duration of use, operation
schedules, and the number of construction workers. Criteria pollutant emissions of
ROG and NOx from these emission sources would incrementally add to the regional
atmospheric loading of ozone precursors during project construction. BAAQMD
CEQA Guidelines recognize that construction equipment emits ozone precursors,
but indicate that such emissions are included in the emissions inventory that is the
basis for regional air quality plans. Therefore, construction emissions would not be
expected to impede attainment or maintenance of ozone standards in the Bay Area
(BAAQMD, 1999). The impact would therefore be less than significant.
The project would result in a net increase in emissions of criteria pollutants (ROG,
NOx and PM-10) primarily because of a resultant increase in average daily vehicle
trips. Based on the traffic analysis, the proposed change in land use would result in
an increase of approximately 886 net daily vehicle trips. Increased vehicle trips
would lead to a small increase in ROG (approximately 3.9 pounds per day), NOx
(approximately 3.7 pounds per day) and PM-10 (approximately 11.5 pounds per
day) due to vehicle exhaust. Increases in emissions from stationary sources at the
site (such as natural gas combustion for space and water heating, landscaping, use
of consumer products, etc.) would also be minimal (approximately 0.08 pounds per
day of ROG and 1.06 pounds per day of NOx). Together, operational emissions
increases resulting from the project would represent approximately ten percent or
less of the quantities BAAQMD identifies as significant (80 pounds per day of
either ROG, NOx, or PM-10, individually. Therefore, once operational, the
development under the Master Plan would not significantly contribute to a violation
of any air quality standard in the area.
Cumulative Air Quality Impact
In combination with other future projects in the project vicinity, the construction
and operations of the proposed project would likely result in a small cumulative
contribution to increases in pollutant emissions, but these would have less than
significant impacts to air quality. Furthermore, with the implementation of
Mitigation Measure AIR-1, these impacts would be reduced to less than significant
levels.
d) Less Than Significant with Mitigation. Construction activities could expose
sensitive receptors (students and residences located adjacent to the project site) to
substantial pollutant concentrations, principally PM-10, from fugitive dust sources.
Initial Study
Palo Alto High School Master Plan 31 ESA / 209002
Initial Study September 2009
However, with implementation of the dust abatement program described above in
Mitigation Measure AIR-1, impacts from construction-related PM-10 emissions
would be less than significant.
The proposed project would locate additional students, considered sensitive receptors, in an
area established with existing scholastic uses and adjacent residential land uses. There are
no major freeways or land uses that would be considered major (i.e., permitted) stationary
sources of air pollution located within the project vicinity (1,000 feet). The only
BAAQMD-identified sources facilities of toxic air contaminant emissions within one-half
mile of the project site is Town & County Cleaners which would not be expected to
represent a threat to the existing school land use or additional students under the Master
Plan as they have changed to their processes to avoid the use of perchlorethylene solvents
since publication of the last BAAQMD toxic report (BAAQMD, 2007).
e) No Impact. As a general matter, the types of land use development that pose
potential odor problems include wastewater treatment plants, refineries, landfills,
composting facilities and transfer stations. No such uses would occupy the project
site. Therefore the project would not create objectionable odors that would affect a
substantial number of people. In addition, there are no existing odor sources in the
vicinity of the project site to which future occupants of the project site would be
subjected.
f) Less than Significant with Mitigation. Gases that trap heat in the atmosphere are
called greenhouse gases. The major concern is that increases in greenhouse gases
are causing global climate change. Global climate change is a change in the average
weather on earth that can be measured by wind patterns, storms, precipitation and
temperature. Although there is disagreement as to the speed of global warming and
the extent of the impacts attributable to human activities, most agree that there is a
direct link between increased emission of greenhouse gases and long-term global
temperature. What greenhouse gases have in common is that they allow sunlight to
enter the atmosphere, but trap a portion of the outward-bound infrared radiation and
warm up the air. The process is similar to the effect greenhouses have in raising the
internal temperature, hence the name greenhouse gases. Both natural processes and
human activities emit greenhouse gases. The accumulation of greenhouse gases in
the atmosphere regulates the earth’s temperature; however, emissions from human
activities such as electricity generation and motor vehicle operations have elevated
the concentration of greenhouse gases in the atmosphere. This accumulation of
greenhouse gases has contributed to an increase in the temperature of the earth’s
atmosphere and contributed to global climate change. The principal greenhouse
gases are carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), sulfur
hexafluoride (SF6), perfluorocarbons (PFCs), hydrofluorocarbons (HFCs), and
water vapor (H2O). Carbon dioxide is the reference gas for climate change because
it is the predominant greenhouse gas emitted. To account for the varying warming
potential of different greenhouse gases, greenhouse gas emissions are often
quantified and reported as CO2 equivalents (CO2e).
Initial Study
Palo Alto High School Master Plan 32 ESA / 209002
Initial Study September 2009
Executive Order S-3-05
In 2005, Governor Schwarzenegger established Executive Order S-3-05, which sets
forth a series of target dates by which statewide emission of greenhouse gasses
(GHG) would be progressively reduced, as follows:
• By 2010, reduce GHG emissions to 2000 levels;
• By 2020, reduce GHG emissions to 1990 levels; and
• By 2050, reduce GHG emissions to 80 percent below 1990 levels.
Assembly Bill 32 (California Global Warming Solutions Act of 2006)
In 2006, California passed the California Global Warming Solutions Act of
(Assembly Bill No. 32; California Health and Safety Code Division 25.5, Sections
38500, et seq., or AB 32), which requires the California Air Resources Board
(CARB) to design and implement emission limits, regulations, and other measures,
such that feasible and cost-effective statewide GHG emissions are reduced to 1990
levels by 2020 (representing an approximate 25 percent reduction in emissions).
Under AB 32, CARB must adopt regulations by January 1, 2011 to achieve
reductions in GHGs to meet the 1990 emission cap by 2020.
CARB Climate Change Scoping Plan
In December 2008, CARB adopted the Climate Change Scoping Plan (AB 32
Scoping Plan) outlining the State’s strategy to achieve the 2020 greenhouse gas
emissions limit. The AB 32 Scoping Plan, developed by CARB in coordination
with the Climate Action Team (CAT), proposes a comprehensive set of
recommended actions designed to reduce overall GHG in California. The measures
in the AB 32 Scoping Plan approved by the Board will be developed over the next
two years and be in place by 2012.
OPR on CEQA and Climate Change
The Governor’s Office of Planning and Research (OPR) June 2008 Technical
Advisory (OPR, 2008) provides informal guidance for public agencies as they
address the issue of climate change in their CEQA documents. The June 2008
Technical Advisory offers recommendations for identifying GHG emissions,
determining significance under CEQA, and mitigating impacts.
The June 2008 OPR Advisory states that lead agencies under CEQA should develop
their own approach to performing a climate change analysis for projects that
generate GHG emissions. The approach should be consistent for analyzing all such
projects, and analyses should be performed based on the best available information.
If a lead agency determines that GHGs may be generated by a proposed project, the
agency is responsible for quantifying estimated GHG emissions by type and source.
The June 2008 OPR Advisory also states that the lead agency must assess whether
project emissions are individually or cumulatively significant and implement
strategies to avoid, reduce, or otherwise mitigate the impacts of those emissions
when impacts are potentially significant. Regional agencies can attempt to reduce
Initial Study
Palo Alto High School Master Plan 33 ESA / 209002
Initial Study September 2009
GHG emissions through their planning processes, according to the June 2008 OPR
Advisory. Regional transportation planning agencies can adopt plans and programs
that address congestion relief and reduce vehicle miles traveled (VMT), for
example.
Subsequent to the release of the 2008 Technical Advisory, OPR has developed
proposed guidelines for the mitigation of GHG emissions or the effects of GHG
emissions under CEQA, following Senate Bill 97. On April 13, 2009, OPR
submitted additions and amendments to the CEQA Guidelines to the Secretary for
Natural Resources for certification and adoption by January 1, 2010.
CARB Preliminary Draft Staff Proposal, October 2008
In its Staff Proposal, CARB is taking the first step toward developing recommended
statewide interim thresholds of significance for GHGs that may be adopted by local
agencies for their own use. The proposal does not attempt to address every type of
project that may be subject to CEQA, but instead focuses on common project types
that, collectively, are responsible for substantial GHG emissions – specifically,
industrial, residential, and commercial projects. CARB is developing these
thresholds in these sectors to advance climate objectives, streamline project review,
and encourage consistency and uniformity in the CEQA analysis of GHG emissions
throughout the State.
CARB staff’s objective in this proposal is to develop a threshold of significance that
will result in the vast majority (approximately 90 percent statewide) of GHG
emissions from new industrial projects being subject to CEQA’s requirement to
impose feasible mitigation. CARB believes this can be accomplished with a
threshold that allows small projects to be considered insignificant. CARB staff used
existing data for the industrial sector to derive a proposed hybrid threshold. The
threshold consists of a quantitative threshold of 7,000 metric tons of CO2 equivalent
per year (MT CO2e/year) for operational emissions (excluding transportation), and
performance standards for construction and transportation emissions. These
performance standards have not yet been developed.
To date, CARB has only developed preliminary interim threshold concepts for
industrial projects. No proposed thresholds for non-industrial project have been
developed.
As with other individual and relatively small projects (i.e., projects that are not
cement plants, oil refineries, electric generating facilities/providers, co-generation
facilities, or hydrogen plants or other stationary combustion sources that emit more
than 25,000 metric tons (MMT) CO2e/yr), the project specific emissions from the
proposed project would not be expected to individually have an impact on global
climate change (AEP, 2007) and the primary concern would be whether the project
would be in conflict with the state goals for reducing greenhouse gas emissions.
Initial Study
Palo Alto High School Master Plan 34 ESA / 209002
Initial Study September 2009
Three types of analyses are used to determine whether the project could be in
conflict with the state goals for reducing greenhouse gas emissions. The analyses
are reviews of:
• Assessment A: The potential conflicts with the CARB 39 recommended actions of the Climate Change Scoping Plan;
• Assessment B: The relative size of the project in comparison to the estimated greenhouse reduction goal of 174 MMTCO2E by 2020 and in comparison to the size of major facilities that are required to report greenhouse gas emissions (25,000 metric tons of CO2E/yr)4 and proposed thresholds of CARB and SCAQMD; and
• Assessment C: The basic parameters of a project to determine whether its design is inherently energy efficient, will lead to wasteful energy use, or is neutral with regard to future energy use.
With regard to Assessment A, the project does not pose any apparent conflict with
the most recent list of the CARB early action strategies as these are aimed at
industry, water use and new land use development.
With regard to Assessment B, project construction GHG emissions were estimated
with the URBEMIS2007 computer model. CO2 emissions from construction
assumed peak annual GHG emissions would most likely occur during Group 1
improvements to the athletic field and would be the result of heavy-duty
construction equipment fine grading an area of approximately 4.8 acres. Per the
Project Description, this work would occur over a nine moth period in 2010 and
2011. GHG emissions from this activity were calculated using the URBEMIS2007
model of the CARB. Equipment exhaust also contains small amounts of methane
and nitric oxides which are also GHGs. Non-CO2 GHG emissions represent
approximately a three percent increase in CO2-equivalent emissions from diesel
equipment exhaust. For purposes of analysis, it was assumed that non-CO2 GHG
emissions from construction equipment would be negligible. The peak annual
activity would generate 410 “short” or 372 metric tons (MT) per year of CO2.
The proposed improvements to Paly under the Master Plan would result in an
increase in daily operational CO2 emissions from project-related traffic and area
source emissions for space and water heating, as well as electricity demand.
Operational emissions of CO2 from vehicle traffic as calculated by URBEMIS2007
would be 1,108 “short” tons per year or 1,005 MT per year. URBEMIS also
calculates natural gas combustion emissions based on square footage of
improvements. CO2 emissions from natural gas emissions are calculated to be 233
“short” tons per year or 211 MT per year. Electricity demand based on square
footage of improvements and California specific emission factors of the California
4 The State of California has not adopted guidance as to quantitative significance thresholds for assessing the impact
of greenhouse gas emissions on climate change and global warming concerns.
Initial Study
Palo Alto High School Master Plan 35 ESA / 209002
Initial Study September 2009
Climate Action Registry and high school-specific electrical demand estimates
would result in an additional 430 MT per year of GHGs emitted indirectly as a
result of the project. Consequently the total CO2 emission rate resulting from
implementation of the proposed Master Plan is estimated to be 1,646 MT per year.
When compared to the state facility reporting requirement for GHG emissions of
25,000 MT per year CO2e, the maximum GHG emissions for the project (372 MT
per year CO2e during construction; and 1,646 MT per year during operations are not
significant enough to require reporting to the CARB relative to the requirements of
AB32. Additionally, although not yet adopted nor applicable to the proposed Master
Plan, project GHG emissions would be less than the proposed 7,000 MT per year
Preliminary Staff Proposal threshold for industrial projects under consideration by
CARB.
With regard to Assessment C, in the absence of any definitive thresholds of
significance, the GHG emphasis on a project-specific level is to incorporate project
design features that reduce energy consumption and reduce vehicular travel as much
as is feasible once such measures are adopted in the Climate Change Scoping Plan
of CARB. Unless there is a greater shift to clean energy such as solar, hydroelectric,
wind, nuclear, etc., no substantial reduction in GHG is likely attainable by
conventional methods except through energy conservation.
GHG reduction options on a project-level basis are similar to those measures
designed to reduce criteria air pollutants (those with ambient air quality standards).
Measures that reduce trip generation or trip lengths, measures that optimize the
transportation efficiency of a region, and measures that promote energy
conservation within a development will reduce GHG emissions.
Because the proposed project consists of improvements under a Master Plan, there
are no specific building details at this level of project development. Consequently,
mitigation measures are recommended to ensure that development under the
proposed Master Plan would be inherently energy efficient and commensurate with
achieving the goals of GHG reductions under AB32.
Mitigation Measure AIR-2: Building development plans resulting from the
Master Plan shall include “green building” features to reduce energy
consumption to the extent practicable. These measures may include:
• Building design consistent with the Collaborative for High Performance
Schools (CHPS). CHPS is a third party program that oversees the
nation’s first green building rating program especially designed for K-12
schools. CHPS has published design guidelines and performance criteria
specific to California schools.
• Install efficient lighting and lighting control systems. Site and design
buildings to take advantage of daylight.
Initial Study
Palo Alto High School Master Plan 36 ESA / 209002
Initial Study September 2009
• Plant trees and vegetation near structures to shade buildings and reduce
energy requirements for heating/cooling.
• Preserve or replace on-site trees consistent with Mitigation Measure
BIO-3 (that are removed due to development) as a means of providing
carbon storage.
• Install light-colored “cool” roofs and cool pavements.
• Install energy efficient heating and cooling systems, appliances and
equipment and control systems.
• Install light emitting diodes (LEDs) for traffic, street and other outdoor
lighting.
• Install water efficient fixtures and appliances.
Implementation of the above mitigation measures would reduce the impact to less than
significant levels.
Sources
Bay Area Air Quality Management District (BAAQMD), BAAQMD CEQA Guidelines:
Assessing the Air Quality Impacts of Projects and Plans, December 1999.
BAAQMD, Toxic Air Contaminant 2003 Annual Report, 2007.
BAAQMD, Rules & Regulations, www.baaqmd.gov/dst/regulations/index.htm, accessed
May 10, 2007.
California Air Resources Board, Air Quality and Land Use Handbook: A Community
Health Perspective, April 2005.
Initial Study
Palo Alto High School Master Plan 37 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
4. Biological Resources
Would the project:
a) Have a substantial adverse effect, either directly or
through habitat modifications, on any species
identified as a candidate, sensitive, or special-status
species in local or regional plans, policies, or
regulations, or by the California Department of Fish
and Game or U.S. Fish and Wildlife Service?
b) Have a substantial adverse effect on any riparian
habitat or other sensitive natural community
identified in local or regional plans, policies,
regulations or by the California Department of Fish
and Game or U.S. Fish and Wildlife Service?
c) Have a substantial adverse effect on federally
protected wetlands as defined by Section 404 of the
Clean Water Act (including, but not limited to, marsh,
vernal pool, coastal, etc.) or state-protected
wetlands, through direct removal, filling, hydrological
interruption, or other means?
d) Interfere substantially with the movement of any
native resident or migratory fish or wildlife species or
with established native resident or migratory wildlife
corridors, or impede the use of native wildlife nursery
sites?
e) Conflict with any local policies or ordinances
protecting biological resources, such as a tree
preservation policy or ordinance?
f) Fundamentally conflict with the provisions of an
adopted Habitat Conservation Plan, Natural
Community Conservation Plan, or other approved
local, regional, or state habitat conservation plan?
Discussion
a) Less than Significant with Mitigation. ESA conducted a reconnaissance-level
field survey of the project area on July 9, 2009 to verify existing biological
conditions, assess vegetation and wildlife habitats, and identify potential for
special-status5 wildlife species to occur on-site (ESA, 2009). Palo Alto and
surrounding cities on the San Francisco peninsula have been extensively developed
in the last century, and while large tracts of open space exist on Stanford University
property approximately 1.5 miles west of the project area, residential areas and
high-traffic roads surround the Paly campus. The project site contains native and
non-native trees including coast live oak (Quercus agrifolia), sycamore (Platanus
racemosa), spruce (Picea sp.), redwood (Sequoia sempervirens), eucalyptus
(Eucalyptus gobulus), magnolia (Magnolia grandiflora), and Monterey cypress
5 The term “special-status” species includes those species that are listed and receive specific protection defined in
federal or state endangered species legislation, as well as species not formally listed as Threatened or Endangered,
but designated as “Rare” or “Sensitive” on the basis of adopted policies and expertise of state resource agencies or
organizations, or local agencies such as counties, cities, and special districts. A principle source for this designation
is the California “Special Animals List” (CDFG, 2009B).
Initial Study
Palo Alto High School Master Plan 38 ESA / 209002
Initial Study September 2009
(Cupressus macrocarpa). Birds identified on campus were species accustomed to
disturbance, including black phoebe (Sayornis nigricans), common raven (Corvus
corax), dark-eyed junco (Junco hyemnalis), European starling (Sturnus vulgaris),
rock dove (Columbia livia), and scrub jay (Aphelocoma californica). Open spaces
without many planted trees are either paved or landscaped grass lawns. Small areas
of ruderal grassland with ripgut brome (Bromus diandrus) and slender wild oats
(Avena barbata) are present within the parking lot and in isolated areas on campus.
The California Natural Diversity Database (CNDDB) documents 43 special-status
species within the Palo Alto and Santa Clara U.S. Geological Survey (USGS)
quadrangles that include the project area (CDFG, 2009). No suitable habitat for
special-status plant species was found on or directly adjacent to the project area,
and it is anticipated that project activities will have no negative effects on special-
status wildlife species except for the pallid bat (Antrozous pallidus), hoary bat
(Lasiurus cinereus), and Townsend’s big-eared bat (Plecotus townsendii).
Construction activities and tree removal may adversely impact nesting birds as well.
These impacts are discussed below.
Special-Status Bats
The pallid bat, hoary bat, and Townsend’s big eared bat could be present in trees or
buildings at Paly. The pallid bat is a California species of concern present in most
low elevations in California. Preferred habitats for the pallid bat include rocky
outcrops with crevices and access to open areas, but they can be found in a variety
of other habitats as well. Day roosts can be found in crevices, caves, mines, and
occasionally hollow buildings and trees, while night roosts can be in more open
areas such as open buildings or porches (Zeiner, et al, 1990). Pallid bats are
nocturnal and present year-round in most areas of California. Local CNDDB
occurrences include Stanford University, and within the cities of Menlo Park and
Woodside (CNDDB, 2009). The hoary bat is a California species of concern and
can be found at nearly any location in California. Maternity roosts of this species
are typically found in woodlands with medium to large trees and dense foliage
cover (Zeiner, et al, 1990). Hoary bats migrate between summer and winter ranges,
but are present year-round in the San Francisco Bay Area. Hoary bats roost in tree
foliage, and less commonly in buildings. Several historical CNDDB occurrences
from nearby Stanford University exist for this species (CNDDB, 2009).
Townsend’s big-eared bat is a California species of special concern also found in
most of California. Roosting habitat includes caves, mines, tunnels, buildings, or
other human-made structures (Zeiner, 1990), and maternity roosts for the
Townsend’s big-eared bat are warm, while hibernation roosts can be cold. This
species is especially sensitive to disturbance, and a single visit by humans may
result in roost abandonment.
Removal of any trees or demolition of buildings containing special-status bat
species in the project area would be a significant impact. This impact can be
Initial Study
Palo Alto High School Master Plan 39 ESA / 209002
Initial Study September 2009
reduced to less-than-significant levels through implementation of Mitigation
Measure BIO-1:
Mitigation Measure BIO-1: PAUSD shall require its contractor(s) to
implement the following measures:
• Prior to construction or demolition activities within 250 feet of trees/structures with at least a moderate potential to support special-status bats, a qualified biologist (i.e., a biologist holding a CDFG collection permit and a Memorandum of Understanding with the CDFG allowing the biologist to handle and collect bats) shall survey for bats. If no evidence of bats (i.e., visual or acoustic detection, guano, staining, strong odors) is present, no further mitigation is required.
• If bats raising pups (also called a maternity colony) are identified within 250 feet of the project area during preconstruction surveys or project construction (typically April 15 through August 15), the PAUSD will create a no-disturbance buffer acceptable in size to the CDFG around the bat roosts. Bat roosts initiated within 250 feet of the project area after construction has already begun are presumed to be unaffected by project-related disturbance, and no buffer would be necessary. However, the “take” of individuals (e.g., direct mortality of individuals, or destruction of roosts while bats are present) is prohibited.
• Trees or buildings with evidence of bat activity will be removed during the time that is least likely to affect bats as determined by a qualified bat biologist (in general, roosts should not be removed if maternity bat roosts are present, typically April 15 – August 15, and roosts should not be removed if present bats are in torpor, typically when temperatures are less than 40 degrees Fahrenheit). Non-maternity bat roosts will be removed by a qualified biologist, by either making the roost unsuitable for bats by opening the roost area to allow airflow through the cavity, or excluding the bats using one-way doors, funnels, or flaps.
• All special-status bat roosts that are destroyed will be replaced at a 1:1 ratio with a roost suitable for the displaced species. The roost will be modified as necessary to provide a suitable roosting environment for the target bat species.
Nesting Birds
Trees in and around the project area provide suitable habitats for breeding birds.
Most native, breeding birds are protected under Section 3503 of the CDFG Code
(Code), and raptors are protected under Section 3503.5 of the Code. In addition,
both Section 3513 of the Code and the Federal Migratory Bird Treaty Act (16 U.S.
Code, Sec. 703 Supp. I, 1989) prohibit the killing, possession, or trading of
migratory birds. Finally, Section 3800 of the Code prohibits the taking of non-game
birds, which are defined as birds occurring naturally in California that are neither
game birds nor fully protected species. To the degree feasible, construction
activities would be scheduled to avoid the nesting season between February 1 and
August 31. In the event construction or vegetation removal must be performed
Initial Study
Palo Alto High School Master Plan 40 ESA / 209002
Initial Study September 2009
during the nesting season, potential impacts to breeding or nesting birds could be
significant and would be minimized to less-than-significant levels with the
implementation of Mitigation Measure BIO-2.
Mitigation Measure BIO-2: If construction or vegetation removal must be
performed in the bird nesting season (February 1 through August 31), a
qualified biologist shall be retained to survey the project area for nesting
raptors and other birds and verify the presence or absence of nesting birds or
raptors no more than 14 days prior to construction activities. If active nests are
observed, buffer zones would be established around trees/shrubs with nests,
with a buffer size established by the qualified biologist through consultation
with the appropriate regulatory agency (e.g., CDFG). Buffered zones would
be avoided during construction activities until young have fledged or the nest
is otherwise abandoned.
b) No Impact. No riparian habitats or other sensitive natural communities exist within
the Paly campus. The nearest sensitive natural communities are the riparian
corridors of San Francisquito Creek, Matadero Creek, and Lake Lagunita, all of
which are more than one mile away from the project area. These riparian corridors
are not close enough to the project area to be directly or indirectly impacted by
project activities.
c) No Impact. Wetlands are a subset of “waters of the United States,” which are
defined in the Code of Federal Regulations (CFR) (33 CFR 328.3[a]; 40 CFR
230.3[s]) as rivers, streams, mud flats, sand flats, wetlands, sloughs, prairie
potholes, wet meadows, playa lakes, or natural ponds, the use, degradation, or
destruction of which could affect interstate or foreign commerce including any such
waters. These waters and their associated riparian corridors fall under the jurisdiction
of the U.S. Army Corps of Engineers, San Francisco Bay Regional Water Quality Control
Board, and the California Department of Fish and Game. The project will not be constructed
within or near any jurisdictional wetland areas, and no impacts on jurisdictional wetlands
by project activities are anticipated.
d) No Impact. Areas around Paly are heavily developed, and any historically present
terrestrial wildlife corridors have already been disrupted. Riparian corridors
discussed in b) and extensive areas of oak savanna west of Paly provide connected
habitats suitable for migration of various wildlife species. Most developed areas of
Palo Alto provide habitat for urban wildlife in landscaped environments, but little
native habitat exists to provide significant wildlife movement corridors around the
project area. Additionally, large roads with high traffic volumes such as El Camino
Real and Embarcadero Road restrict movement of many terrestrial wildlife species
through the project area. No impacts on wildlife corridors are anticipated by project
activities.
Initial Study
Palo Alto High School Master Plan 41 ESA / 209002
Initial Study September 2009
e) Less than Significant with Mitigation. Many large trees grow within the project
area, and proposed construction of new facilities may necessitate tree removal.
Under the City of Palo Alto Tree Preservation and Management Regulations
(Municipal Code Section 8.10) and the Tree Technical Memo (City of Palo Alto,
2001), trees designated as protected trees or street trees are subject to several
conditions before removal. A protected tree is:
• A coast live oak (Quercus agrifolia) or valley oak (Quercus lobata) tree greater than 11.5 inches diameter at breast height (DBH)6;
• A redwood (Sequioa sempervirens) tree greater than 18 inches DBH; or
• Any tree designated a heritage tree by the Palo Alto city council.
• A street tree is any tree that grows within the publicly-owned street right-of-way.
Removal of any protected or street trees in the project area would be considered a
significant impact. These impacts can be mitigated to less-than-significant levels
through Mitigation Measure BIO-3.
Mitigation Measure BIO-3: PAUSD shall require its contractor(s) to
implement the following measures:
• Fulfill pre-construction requirements consistent with Section 2.15 of the City of Palo Alto Tree Technical Memo, including establishment of a tree protection and preservation plan; verification of tree protection; a pre-construction meeting with the City Arborist, community representative, and District Arborist to coordinate a tree replacement plan and protective fencing for retained protected or street trees; establishment of tree protection zones for retained trees; and trimming of any retained trees.
• Obtain a tree removal permit for removal of any street trees in the project area by submitting the following to the City of Palo Alto:
1) Protected Tree Removal Application;
2) Application fees; and
3) Letter report from a certified arborist including tree species,
location, size (DBH, height and crown spread), condition, and life
expectancy and prognosis.
• Obtain a permit from the City of Palo Alto Department of Public works for any construction activities occurring within the dripline7 of a street tree.
6 Diameter at breast height (DBH) is the diameter of the trunk of a tree 4.5 feet above natural grade.
7 Dripline area, as defined in the Tree Technical Manual, is the circular area underneath a tree with a radius equal to
ten times the tree’s trunk diameter.
Initial Study
Palo Alto High School Master Plan 42 ESA / 209002
Initial Study September 2009
• Remove no more than 25 percent of a protected tree’s canopy during
pruning activities of retained trees, and remove no more than 25 percent
of a protected tree’s root mass during construction activities.
• Replace all removed street trees as specified by the City of Palo Alto’s
Director of Planning and Community Environment and in conjunction
with standards described in section 3.15-C in the City of Palo Alto Tree
Technical Manual.
f) No Impact. The proposed project would not conflict with the provisions of an
adopted Habitat Conservation Plan, Natural Community Conservation Plan, or other
approved local, regional, or state habitat conservation plan. Mitigation Measures
BIO-1, BIO-2, and BIO-3 are designed to reduce cumulative impacts to special-
status species and wetlands, and avoid conflicts with any other local plans or
ordinances.
Sources
California Department of Fish and Game (CDFG), California Natural Diversity Database
for 7.5 minute topographic quadrangles of Mountain View, Palo Alto, Commercial
Version, accessed July, 2009.
CDFG, California Natural Diversity Database. Special Animals (901 Taxa),
www.dfg.ca.gov/biogeodata/cnddb/pdfs/SPAnimals.pdf, accessed July 2009.
City of Palo Alto, Department of Planning and Community Environment, Tree Technical
Manual, 2001.
City of Palo Alto Municipal Code, Section 8.10,
www.cityofpaloalto.org/depts/clk/municipal_code.asp, accessed July 15, 2009.
ESA, Site reconnaissance, July 9, 2009.
Zeiner, D.C., Laudenslayer, W.F., Mayer, W.E., and White, M., ed., California’s
Wildlife, Volume III, Mammals, California Department of Fish and Game,
Sacramento, CA, 1990.
Initial Study
Palo Alto High School Master Plan 43 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
5. Cultural Resources
Would the project:
a) Cause a substantial adverse change in the
significance of a historical resource as defined in
§15064.5?
b) Cause a substantial adverse change in the
significance of a unique archaeological resource
pursuant to §15064.5?
c) Directly or indirectly destroy a unique paleontological
resource or site or unique geologic feature?
d) Disturb any human remains, including those interred
outside of formal cemeteries?
Discussion
a) Less Than Significant with Mitigation. CEQA Guidelines Section 15064.5
requires the lead agency to consider the effects of a project on historical resources.
A historical resource is defined as any building, structure, site, or object listed in or
determined to be eligible for listing in the California Register of Historical
Resources (CRHR), or determined by a lead agency to be significant in the
architectural, engineering, scientific, economic, agricultural, educational, social,
political, or cultural annals of California. The following discussion will focus on
architectural/structural resources. Archaeological resources, including
archaeological resources that are potentially historical resources according to
Section 15064.5, are addressed in b), below.
The Palo Alto Unified School District (PAUSD or District) was founded in 1893. The
District includes the City of Palo Alto, Stanford University, and areas of Los Altos
Hills, Palo Alto Hills, and Portola Valley within its attendance area. The Paly High
School campus consists of 17 buildings constructed between 1918 and 2004. The
original construction in 1918 included the Administration and Classroom Building
and the Auditorium Building (also known as the “Haymarket Theater”). Much of the
original administration/classroom structure was demolished in 1972, leaving the two-
story portion referred to as the “Tower Building.” In 1928, the original Boys’
Gymnasium was constructed. The construction of the Industrial Arts Building was
completed in 1945 and expanded to include an electronics classroom in 1955. The
Boys’ Gymnasium was expanded in 1946 to provide locker and shower facilities and
staff offices. In 1960, the Science Classroom Building was constructed. The addition
of the Girls’ Gymnasium and the swimming pool was completed in 1969. In 1968,
the Administration Building, Auditorium, and the Boys’ Gymnasium were
extensively renovated as part of seismic retrofitting. The majority of the other
buildings on campus were constructed in the early 1970s.
Initial Study
Palo Alto High School Master Plan 44 ESA / 209002
Initial Study September 2009
Palo Alto High School’s Haymarket Theater and Tower Building are the last
remaining connections to the original campus construction. Completed in 1918 and
designed by the Los Angeles architecture firm of Allison and Allison in a Spanish
Colonial Revival style of architecture, these highly visible buildings are a long-
established presence in the community as a whole. The Tower Building in particular
is seen as an icon and a defining image for the campus. While neither building is
listed on the state or federal registers of historic resources, the City of Palo Alto
does include these buildings on its Historic Resources Inventory. The Inventory
identifies the Tower Building and the Theater as Category 2 buildings, defined as
“any building or group of buildings of major regional importance, meritorious
works of the best architects, or an outstanding example of an architectural style or
the stylistic development of architecture of the state or region. A major building
may have some exterior modifications, but the original character is retained.”
Because these buildings are listed in the Palo Alto Historic Resources Inventory as
Category 2 structures, the Palo Alto High School’s Haymarket Theater and Tower
Building are considered historical resources under CEQA Guidelines Section
15064.5.
Provided below is a description of the exterior and interior features of each
building, as well as an evaluation of the potential effects of the proposed project on
these historic resources.
Haymarket Theater
Much of the Theater building’s historic and architectural character resides in the
main entry façade. A rooftop cupola and the arcade that connects the Theater
Building to the Tower Building are also features that retain the historic and
architectural qualities of the original campus. The roof tile, shared with the Tower
Building, is another aspect of the original construction of the campus that carries
historical import. The main entry facade has experienced some significant
deterioration over the years; ornamentation such as the owls on top of the columns
have been removed, the spiral, terra cotta columns are cracked in a number of
places, original lighting has been removed, original doors have been removed and
replaced, and years of wear and tear have generated the need to repair or replace
windows, etc. A structural upgrade in 1934 removed a number of features from the
building including high windows along each side of the auditorium. The interior of
the auditorium was stripped almost entirely of its original character. Originally open
to the roof structure above, the auditorium had a ceiling and structural bracing
installed, which obscured the original structure from view. High windows were also
filled in at this time, and a continuous ceiling and wall finish of striated plaster was
installed. New light fixtures were added in the 1930s remodel. These alterations
have an Art Deco style to them, which diverge from the Spanish Colonial Revival
exterior of the building. The 1930s alterations, which occurred relatively early in
the building’s history, may have achieved significance in their own right, however,
and may help to convey the evolution of the building over time, including
Initial Study
Palo Alto High School Master Plan 45 ESA / 209002
Initial Study September 2009
improvements in seismic strengthening technology between 1918 and the mid-
1930s.8 As such, it is possible that the interior of the building also retains some
degree of architectural merit.
The Haymarket Theater would be renovated under Group 5 of the proposed project.
The proposed project would “modernize the existing building with limited building
modifications to address accessibility issues.” Such activities would include new
Americans with Disabilities (ADA) accessible entrances, ADA compliant stairs and
handrails, ADA compliant restrooms, an accessible drinking fountain, exterior and
interior ramps, and installation of an assistive listening system. Although the
majority of the renovations would occur in the interior of the building, which was
altered early in the building’s history, it is possible that the new proposed
improvements such as the ADA entrances and ramps could also alter the building’s
exterior character defining features.
As no systematic evaluation of the building’s exterior or interior character-defining
features have been prepared, nor have final project plans been completed, the
proposed project could have an adverse impact on the historic significance of the
Haymarket Theater if they were not completed in a manner consistent with the
Secretary of the Interior’s Standards for Rehabilitation, which would be considered
a significant impact on the environment under CEQA. CEQA Section 15064.5(b)(3)
states that, “Generally, a project that follows the Secretary of the Interior’s
Standards for Rehabilitation and Guidelines for Rehabilitating Historic Buildings
(Weeks and Grimmer, 1995) shall be considered mitigated to a level of les than a
significant impact on the historical resource.” As both the full extent of the
building’s interior and exterior character-defining features are unknown, and given
the lack of specificity of the proposed renovation efforts, it is conservatively
concluded that the proposed project could have a significant impact on the historic
significance of this building. Mitigation measures proposed to reduce the potential
impact to a less-than-significant level are provided below
Tower Building
The Tower Building’s historic character is expressed on all exterior facades and is
highlighted by the original bell tower or campanile. The Spanish tile roof and
arcade also reflect the character of the original campus. Elaborate terracotta
ornamentation at the main entry is in relatively good condition. At the side (parking
lot) entrance, the terracotta trim is somewhat deteriorated, portions are missing, and
columns have been obscured by paint. Terracotta trim at the arcade is covered with
layers of paint. The tall wood casement windows, a defining feature of the Tower
Building, are in poor repair. Doors are generally neither original nor appropriate to
8 These structural improvements were likely made to the Haymarket Theater in compliance with more stringent
seismic building requirements for all schools in California as a result of the devastating 1933 Long Beach
Earthquake, which destroyed numerous civic and academic buildings throughout Southern California.
Initial Study
Palo Alto High School Master Plan 46 ESA / 209002
Initial Study September 2009
the building style and many are not weather tight. Modern exterior lighting has been
added that is out of character with the original building.
The interior layout/plan of the building is substantially intact, though historic light
fixtures and finishes have been replaced with elements not in keeping with the
building’s historic character. The building’s showpiece, the original library, is a
grand vaulted space with its original wood structure exposed at the ceiling and is
flooded with light from the very tall windows wrapping three sides. This room is
currently divided by interior partial-height partitions that house the school’s
Guidance and Counseling Offices. The ceiling is still visible, however, above these
partitions. Interior finishes are showing obvious signs of age and wear. Floor
finishes at the corridors are in poor condition, and glued-on ceiling tiles are loose in
many locations.
The Tower Building would be renovated in two phases under Group 4c and Group
5a of the proposed project, respectively. Under Group 4a, the proposed project
would complete “minimum upgrades required for safety, building integrity, and
code compliance,” including the following: 1) upgrading the existing structural
system to meet FEMA guidelines; 2) replacing windows in original Library for
safety; 3) replacing/repairing select other windows that are damaged; and 4)
numerous ADA upgrades, including elevator access to the second floor by inserting
an elevator into the existing tower (requires shoring and deepening of tower
foundations) or by appending a new elevator structure, which would provide
accessible student and staff toilets on both floors, create accessible entrances,
including ramps, at major entry points, modifying existing stairs where needed for
accessibility code compliance, and replacing existing doors, frames, and hardware.
Group 4c of the project improvements would also include: 5) mechanical upgrades,
including changes to floor, wall, and ceiling finishes, and retrofit of existing stair
tread heights. Finally, Group 4c work would also include: 7) replacing existing
lighting where disturbed by work; and 8) upgrading fire protection measures to
meet current standards.
Under Group 5a, the proposed project would include all of the above work under
Group 4c, plus “upgrade building systems to meet campus standards, and modify
existing layout,” including the following activities: 1) reconfiguring spaces/relocate
users of existing spaces, including removing existing non-shear walls and
reconfigure spaces for improved utility; replace existing bearing walls with
beams/columns as required, remodel original library space to serve a more-public
function, (e.g., lecture hall/meeting room/gallery); 2) replacing additional windows
as required by new wall locations; 3) replacing all windows with new double-
paned, Low-E windows for increased energy efficiency and thermal comfort; 4)
ADA upgrades (see discussion above under Group 4c); 5) additional mechanical
upgrades; and 6) additional electrical upgrades.
Initial Study
Palo Alto High School Master Plan 47 ESA / 209002
Initial Study September 2009
As no systematic evaluation of the building’s exterior or inter character-defining
features have been prepared, nor have final project plans been completed, the
proposed project could have a significant adverse impact on the historic
significance of the Tower Building if they were not completed in a manner
consistent with the Secretary of the Interior’s Standards for Rehabilitation, which
would be considered a significant impact on the environment under CEQA. CEQA
Section 15064.5(b)(3) states that, “Generally, a project that follows the Secretary of
the Interior’s Standards for Rehabilitation and Guidelines for Rehabilitating
Historic Buildings (Weeks and Grimmer, 1995) shall be considered mitigated to a
level of les than a significant impact on the historical resource.” As both the full
extent of the building’s interior and exterior character-defining features are
unknown, and given the lack of specificity of the proposed renovation efforts, it is
conservatively concluded that the proposed project could have a potentially
significant impact on the historic significance of this building. Mitigation measures
proposed to reduce the potential impact to a less-than-significant level are provided
below.
Aside from potential direct effects to the Haymarket Theater and Tower Building
described above, no other direct or indirect impacts to historic resources either on or
off campus are anticipated as a result of the proposed project. The addition to the
Student Center under Group 6a of the proposed project, however, would be
constructed approximately 30 feet to the east of the Tower Building. This proposed
addition would have no significant indirect effects to the historic setting of the
Tower Building, given the sufficient distance between these buildings, which would
allow the Tower Building to continue to “read” as a separate structure. The
proposed addition would also be subordinate to the Tower Building, and while its
design of this new building has not been finalized, it is intended to be
architecturally compatible not only with the Tower Building, but other buildings on
the Paly campus. As such, the proposed addition to the Student Center would have
no direct or indirect effects to historic architectural resources on the Paly campus.
Other proposed structures on the campus, such as the future theater and gym, would
be located approximately 200 feet and 430 feet from both the Haymarket Theater
and the Tower Building, respectively. Given these relatively wide separations
between the historic resources and the proposed new buildings, there would be no
indirect effects on the setting of historic resources at the Paly campus as a result of
these new structures. Public views of the Tower Building, in particular, would
continue to be available from El Camino Real, and its campanile would remain a
visible icon for both the campus and the immediate neighborhood.
Mitigation Measure CUL-1. The PAUSD shall hire a qualified consulting
architectural historian to review the architectural plans for renovations to both
the Haymarket Theater and Tower Building for compliance with the Secretary
of the Interior’s Standards for Rehabilitation. A description of the Standards
is provided in Appendix A. Given that the Standards for Rehabilitation allow
Initial Study
Palo Alto High School Master Plan 48 ESA / 209002
Initial Study September 2009
a fair degree of flexibility and latitude in alterations to historic resources for
code compliance while attempting to retain the majority of the building’s
character-defining features, it appears possible that the proposed renovation
efforts could meet the Standards.
The consulting architectural historian shall provide the District with an
assessment of compliance with the Standards in the form of a brief technical
memorandum, including recommended design changes for a more complete
compliance with the Standards, if necessary. During final plan check review,
the District shall evaluate whether the recommended design changes by the
consulting architectural historian, if proposed, are reflected on the final
designs for the renovation of the Haymarket Theater and Tower Building.
Implementation of this mitigation measure would reduce the project’s potentially
significant impact to historic resources to a less-than-significant level.
b) Less Than Significant with Mitigation. This section discusses archaeological
resources, both as historical resources according to Section 15064.5 as well as
unique archaeological resources as defined in Section 21083.2 (g).
A records search was conducted at the Northwest Information Center of the
California Historical Resources Information System (NWIC) at Sonoma State
University on June 29, 2009 (File No. 08-1672) to: (1) determine whether known
archaeological resources had been recorded within a 0.5 mile radius of the project
site; (2) assess the likelihood for unrecorded archaeological resources to be present
based on historical references and the distribution of nearby archaeological sites;
and (3) develop a context for the identification and preliminary evaluation of
cultural resources. During the records search, the following sources for information
on historical resources were reviewed: the California Inventory of Historical
Resources (OHP, 1976), California Historical Landmarks (DPR, 1996), California
Points of Historical Interest (DPR, 1992), and Historic Properties Directory Listing
(OHP, 2009). The Historic Properties Directory includes listings of the National
Register of Historic Places and the California Register of Historical Resources, and
the most recent listings of California Historical Landmarks and California Points of
Historical Interest. Historic topographic maps were also reviewed.
The project site is situated within the territory of the Costanoan—also referred to as
Ohlone—language groups. Eight Costanoan languages were spoken in an area
extending from the southern edge of the Carquinez Strait to portions of the Sur and
Salinas Rivers south of Monterey Bay (Levy, 1978). At the time of Euro-American
contact, Ramaytush speakers occupied the San Francisco Peninsula.
Levy’s 1978 summary of Costanoan lifeways describes territories as comprised of
one or more land-holding groups, which anthropologists named tribelets. The
tribelet, or village community, was a nearly universal characteristic throughout
Native California, consisting of a principal village that was occupied year-round
Initial Study
Palo Alto High School Master Plan 49 ESA / 209002
Initial Study September 2009
and a series of smaller hamlets occupied intermittently or seasonally (Kroeber,
1925). Tribelet territories were generally defined on the basis of physiographic
features (e.g., river drainage systems) and stretched between 8 and 12 miles across.
Population densities within tribelets ranged from 50 to 500 people and were largely
determined by the carrying capacity of a tribelet’s territory. San Francisquito Creek,
located approximately one-mile northwest of the project site, was one of the most
densely occupied watersheds along the San Francisco Peninsula during the
prehistoric period. At the time of Euroamerican contact, two or more Ohlone
tribelets may have occupied this watershed at the villages of puyšon and Ssiputca.
No archaeological resources have been recorded in the project site or within a 0.5
mile radius of the project site. The project site is located in an area mapped as late
Pleistocene or early Holocene alluvium. This geologic landform has a low potential
to contain deeply-buried soils or paleosols that would have once been available for
human use and occupation. The project site has a low potential to contain
archaeological materials, however the possibility cannot be entirely discounted. The
following mitigation measure will to reduce potential impact to the inadvertent
discovery of archaeological resources to a less-than-significant level.
Mitigation Measure CUL-2: If previously unidentified cultural materials are
unearthed during construction, work should halt in that area until a qualified
archaeologist can assess the significance of the find. Additional archaeological
survey will be needed if project limits are extended beyond the present study
limits. Prehistoric materials might include obsidian and chert flaked-stone
tools (e.g., projectile points, knives, scrapers) or toolmaking debris; culturally
darkened soil (“midden”) containing heat-affected rocks, artifacts, or shellfish
remains; and stone milling equipment (e.g., mortars, pestles, handstones, or
milling slabs); and battered stone tools, such as hammerstones and pitted
stones. Historic-era materials might include stone, concrete, or adobe footings
and walls; filled wells or privies; and deposits of metal, glass, and/or ceramic
refuse. If any find is determined to be significant, the project proponent and
the archaeologist will meet to determine the appropriate avoidance measures.
If the resources cannot be avoided they must be evaluated for their eligibility
to the California Register of Historical Resources.
c) Less Than Significant with Mitigation. Paleontological resources are the
fossilized remains of plants and animals, including vertebrates (animals with
backbones), invertebrates (e.g., starfish, clams, ammonites, and marine coral), and
fossils of microscopic plants and animals (microfossils). The age and abundance of
fossils depend on the location, topographic setting, and particular geologic
formation in which they are found. Fossil discoveries provide scientific value
because they help establish a historical record of past plant and animal life and can
assist geologists in dating rock formations.
Initial Study
Palo Alto High School Master Plan 50 ESA / 209002
Initial Study September 2009
Subsurface excavations into undisturbed soils and rock beneath the high school
could potentially disturb or destroy paleontological resources. Paly is underlain by
Pleistocene-age (10,000 to 1.8 million years ago) alluvial fan and fluvial deposits,
which are characterized by sequences of sand, silt and gravel that form gently
sloping surfaces. These deposits originated from modern stream courses, which
now deposit their sediment loads closer to the bay and in narrow stream valleys.
Thus, these “stabilized” alluvial fan deposits are old enough to have stiffened and
preserved the remains of Pleistocene organisms.
In fact, Pleistocene alluvium in California is well known for yielding fossils of
extinct vertebrate mammals. Geologic mapping indicated that the unit locally
contains fresh-water mollusks and extinct late Pleistocene vertebrate fossils (USGS,
2000). In addition, the University of California Museum of Paleontology database
records show that similar deposits have yielded vertebrate fossils at eight different
locations in San Mateo County (UCMP, 2009). These include fossils from a bison,
mammoth, camel, horse, sloth and moose, as well as one bird species. The fossils
were found in locations along the Pacific coast as well as along Skyline Drive in
South San Francisco and along Middlefield Road in San Mateo County. The
database did not have specific information on the location of the non-coastal fossils.
Because the Pleistocene alluvial fan and fluvial deposits beneath Paly have yielded
vertebrate fossils, it qualifies under the Society of Vertebrate Paleontology
guidelines as a unit of high paleontological potential9 (SVP, 2006). While no
information exists to refute or confirm the presence of fossils beneath the high
school, and because the unit has a high paleontological potential, subsurface
excavations beyond previously disturbed soils could disturb or destroy
paleontological resources, which would be potentially significant impact.
Mitigation Measure CUL-3 would reduce this impact to a less than significant level
by educating earth moving crews on the appearance of fossils, procedures to follow
if any are discovered, and ensuring that a paleontologist assess the significance of
any fossil find, and recovers it, if appropriate.
Mitigation Measure CUL-3: Prior to the start of any subsurface excavations,
all construction forepersons and field supervisors shall receive training by a
qualified professional paleontologist, as defined by the SVP (1995), who is
experienced in teaching non-specialists, to ensure they can recognize fossil
materials and will follow proper notification procedures in the event any are
uncovered during construction. Procedures to be conveyed to workers include
halting construction within 50 feet of any potential fossil find and notifying a
qualified paleontologist, who will evaluate its significance. Training on
paleontological resources will also be provided to all other construction
workers, but may involve using a videotape of the initial training and/or
9 Paleontological potential refers to the probability that a rock unit will yield a unique or significant paleontological
resource.
Initial Study
Palo Alto High School Master Plan 51 ESA / 209002
Initial Study September 2009
written materials rather than in-person training by a paleontologist. If a fossil
is determined to be significant and avoidance is not feasible, the
paleontologist will develop and implement an excavation and salvage plan in
accordance with SVP standards (SVP, 1995; SVP, 1996).
d) Less than Significant with Mitigation. Based upon the records search, no human remains are
known to exist within the project site. The proposed project will involve ground-disturbing
activities; therefore the possibility that such actions could unearth, expose, or disturb
buried human remains cannot be entirely discounted. The following mitigation measure
would reduce potential impacts attributable to the inadvertent discovery of human
remains to a less-than-significant level.
Mitigation Measure CUL-4: If human remains are encountered unexpectedly
during construction excavation and grading activities, State Health and Safety
Code Section 7050.5 requires that no further disturbance shall occur until the
County Coroner has made the necessary findings as to origin and disposition
pursuant to PRC Section 5097.98. If the remains are determined to be of
Native American descent, the coroner has 48 hours to notify the Native
American Heritage Commission (NAHC). The NAHC will then identify the
person(s) thought to be the Most Likely Descendent of the deceased Native
American, who will then help determine what course of action should be
taken in dealing with the remains.
Sources
California Department of Parks and Recreation (DPR), Historic Resources Inventory
Form, Palo Alto Senior High School. Prepared by the City of Palo Alto. Historic
Resource Board. 1978, 1981.
California Department of Parks and Recreation (DPR), California Points of Historical
Interest, Office of Historic Preservation, Sacramento, California, 1992.
California Department of Parks & Recreation (DPR), California Historical Landmarks,
Sacramento: State of California, Resources Agency, 1996.
HMC Architects, Palo Alto Unified School District, Planning Study for Palo Alto High
School Theater and Tower Buildings, June 2006.
Kroeber, Alfred L., Handbook of the Indians of California. Bureau of American
Ethnology Bulletin 78. Smithsonian Institution, Washington, D.C., Reprinted 1976
by Dover, New York, 1925.
Levy, Richard, Costanoan in California, Handbook of North American Indians, Vol. 8,
William C. Sturtevant, general editor, 1978.
Society of Vertebrate Paleontology (SVP), Assessment and mitigation of adverse impacts
to nonrenewable paleontologic resources: standard guidelines, Society of
Vertebrate Paleontology News Bulletin, Vol. 163, 1995.
Initial Study
Palo Alto High School Master Plan 52 ESA / 209002
Initial Study September 2009
Society of Vertebrate Paleontology (SVP), Conditions of Receivership for Paleontologic
Salvage Collections, Society of Vertebrate Paleontology News Bulletin, Vol. 166,
February 1996.
University of California Museum of Paleontology (UCMP), Collections Database,
www.ucmp.berkeley.edu/science/collections.php, accessed August 20, 2009.
United States Geological Society (USGS), Geologic map and map database of the Palo
Alto 30’ X 60’ quadrangle, California, Prepared by Brabb E.E., Graymer R.W., and
Jones D.L., USGS Miscellaneous Field Studies, Map MF-2332, Version 1.0, 2000.
Initial Study
Palo Alto High School Master Plan 53 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
6. Geology and Soils
Would the project:
a) Expose people or structures to potential substantial
adverse effects, including the risk of loss, injury, or
death involving:
Rupture of a known earthquake fault, as delineated on the
most recent Alquist-Priolo Earthquake Fault Zoning Map
issued by the State Geologist for the area or based on
other substantial evidence of a known fault? Refer to
Division of Mines and Geology Special Publication 42.
Strong seismic ground shaking?
Seismic-related ground failure, including liquefaction?
Landslides?
b) Result in substantial soil erosion or the loss of topsoil?
c) Be located on geologic unit or soil that is unstable, or
that would become unstable as a result of the project,
and potentially result in on- or off-site landslide, lateral
spreading, subsidence, liquefaction, or collapse?
d) Be located on expansive soil, as defined in
Table 18-1-B of the Uniform Building Code (1994, as it
may be revised), creating substantial risks to life or
property?
e) Have soils incapable of adequately supporting the use
of septic tanks or alternative wastewater disposal
systems where sewers are not available for the
disposal of wastewater?
Setting
The City of Palo Alto is located along the southern portion of the San Francisco
Peninsula. The landscape is typical of much of the California Coast Ranges, characterized
mainly by northwest trending ridges and valleys of moderate topographic relief. The area
is also characterized by numerous active and potentially active faults, and frequent
earthquakes. The San Andreas Fault, a major tectonic and structural feature of the Coast
Range that bisects the City’s foothill area, forms the boundary between the North
American and Pacific plates.
The greatest hazards associated with earthquakes are fault rupture and groundshaking,
although liquefaction hazards are significant east of U.S. Highway 101 (U.S. 101) due to
the porous nature and relatively shallow groundwater table. Other geologic hazards in
Palo Alto may or may not include landslides, expansive soils, settlement, and erosion.
Landsliding may result from heavy rain, erosion, removal of vegetation, or human
activities. Settlement and subsidence due to groundwater withdrawal has historically been
a problem in south and east Palo Alto but has been largely halted by groundwater
recharge efforts and reduced pumping from local groundwater resources. Seismically-
induced flooding is a hazard due to the possibility of dam failure at Felt Lake, Searsville
Initial Study
Palo Alto High School Master Plan 54 ESA / 209002
Initial Study September 2009
Lake, and Lagunita Reservoir, as well as from the potential for levee failure near San
Francisco Bay.
Discussion
a.i) Less than Significant. Surface fault rupture is most commonly seen along traces of
active faults during major earthquakes and results in observable offsets on the
ground surface. On faults that generate horizontal movement (referred to as strike-
slip faults) this displacement along a fault trace can cause considerable damage to a
structure, even collapse. Non-structural damage from fault rupture includes
distorted asphalt, severe utility damage, distressed foundations and extensive
service disruption for transportation facilities. Surface fault rupture presents a
substantial potential risk to people and property, especially in the San Francisco
Bay Area where there are several active faults.
The project site is located approximately 5.3 miles from the San Andreas Fault and
3.4 miles from the potentially active Monte-Vista-Shannon fault. The State of
California, through the Alquist-Priolo Earthquake Fault Zoning Act (Alquist-Priolo
Act), prohibits the development of structures for human occupancy across active
fault traces,10 Under the Alquist-Priolo Act, the California Geological Survey
(CGS) must establish zones on either side of the active fault that delimit areas most
susceptible to surface fault rupture. These zones are referred to as fault rupture
hazard zones and are shown on official maps published by the CGS. The project
site is not located in an Alquist-Priolo Earthquake Fault Zone, as defined by CGS.
The geotechnical investigation (Cleary, 2009) concluded that there are no known
active or potentially active faults crossing the proposed building sites. Therefore,
the hazard resulting from surface fault rupture at the project site is considered low
and the impact is considered less than significant.
a.ii) Less than Significant with Mitigation. Seismic ground shaking is a significant
hazard within Palo Alto because of its close proximity to the San Andreas Fault, the
Hayward Fault, the front-range fault system, and several other faults within the Bay
Area that have the capability of producing a large magnitude earthquake. The level
of shaking is influenced by various factors including distance to the epicenter,
underlying soil or bedrock conditions, and the magnitude of the event.
In April 2008, a new earthquake forecast called the Uniform California Earthquake
Rupture Forecast (UCERF) was released that updated the earthquake forecast for
the Bay Area. Produced by the U.S. Geological Survey 2007 Working Group on
California Earthquake Probabilities (WG07), the UCERF evaluated the likelihood
10 An active fault is defined by the State of California as a fault that has had surface displacement within Holocene
time (approximately the last 10,000 years). A potentially active fault is defined as a fault that has shown evidence
of surface displacement during the Quaternary (last 1.6 million years), unless direct geologic evidence demonstrates
inactivity for all of the Holocene or longer. This definition does not, of course, mean that faults lacking evidence of
surface displacement are necessarily inactive. Sufficiently active is also used to describe a fault if there is some
evidence that Holocene displacement occurred on one or more of its segments or branches (Hart, 1997).
Initial Study
Palo Alto High School Master Plan 55 ESA / 209002
Initial Study September 2009
of one or more earthquakes of moment magnitude 6.7 or higher occurring in the
San Francisco Bay Area.11 The result of the evaluation indicated a 63 percent
likelihood that such an earthquake event will occur in the Bay Area before 2037.
Within this 63 percent probability, the Hayward-Rodgers Creek and San Andreas
Fault systems are the two most likely fault systems to cause the event (UCERF,
2008). Therefore, the proposed project would likely experience at least one major
earthquake (greater than moment magnitude 6.7) before 2037.
According to the CGS Probabilistic Seismic Hazard Assessment (PSHA), peak
ground acceleration at the project site could reach or exceed 0.5 g (CGS, 2009).12
The PSHA identifies the hazard from earthquakes that geologists and seismologists
agree could occur. It is “probabilistic” in the sense that the analysis takes into
consideration the uncertainties in the size and location of earthquakes and the
resulting ground motions that can affect a particular site.
In addition, the Association of Bay Area Governments (ABAG) determined that
ground shaking at the project site would most likely be felt as very strong if a
moment magnitude 7.2 earthquake were to occur on the San Andreas Fault Zone
(ABAG, 2009).
Ground shaking from a moderate to strong earthquake could generate ground
accelerations at the proposed project site that could cause damage to structures,
utilities, and/or unsecured equipment and objects. Specifically, the proposed school
buildings and underground utilities could sustain structural damage, potentially
causing injury to anyone present during an earthquake event. Damage from ground
shaking could include cracking in walls and pavement and damage to exterior
building elements.
Although some structural damage is typically not avoidable during an earthquake,
current building codes and construction ordinances have been established to protect
against building collapse and major injury during a seismic event. Implementation
of Mitigation Measure GEO-1 would ensure that impacts related to seismic ground
shaking would be less than significant.
Mitigation Measure GEO-1: The proposed construction shall comply with
site specific recommendations made in design level geotechnical
investigations by the District’s geotechnical engineers. These
recommendations shall be designed to mitigate geologic hazards and shall
become part of the project. The final seismic considerations shall be submitted
11 Moment magnitude is related to the physical size of a fault rupture and movement across a fault. The Richter
magnitude scale reflects the maximum amplitude of a particular type of seismic wave. Moment magnitude provides
a physically meaningful measure of the size of a faulting event (CGS, 1997).
12 “g” is equivalent to the acceleration due to gravity, or 980 centimeters per second squared. Acceleration is scaled
against acceleration due to gravity or the acceleration with which a ball falls if released at rest in a vacuum (1.0 g).
Acceleration of 1.0 g is equivalent to a car traveling 100 meters (328 feet) from rest in 4.5 seconds.
Initial Study
Palo Alto High School Master Plan 56 ESA / 209002
Initial Study September 2009
to and approved of by the Division of the State Architect (DSA), prior to
project commencement, to ensure compliance with the most current California
seismic building codes.
a.iii) Less than Significant. Liquefaction is the sudden temporary loss of shear strength
in saturated, loose to medium dense, granular sediments subjected to ground
shaking. It generally occurs when seismically induced ground shaking causes pore
water pressure to increase to a point equal to the overburden pressure. Liquefaction
can cause foundation failure of buildings and other facilities due to the reduction of
foundation bearing strength.
The State of California, through the Seismic Hazard Zonation Program, produces
Seismic Hazard Zone maps that identify areas of liquefaction and landsliding, as
required by the Seismic Hazards Mapping Act. These maps depict “areas where
historical occurrence of liquefaction, or local geological, geotechnical and ground
water conditions indicate a potential for permanent ground displacement such that
mitigation as defined in Public Resources Code Section 2693(c) would be
required.” The CGS Seismic Hazard Zone map for the Palo Alto Quadrangle (CGS,
2006) does not indicate any liquefaction areas on the project site.
The geotechnical investigation (Cleary, 2009) concluded that the likelihood of soil
liquefaction during strong ground shaking to be very low; however, the sand and
clay layers encountered in borings below the theoretically high groundwater table
(estimated at 25 feet) were conservatively analyzed for liquefaction-induced
settlement. Based on the results of the analysis, theoretical liquefaction-induced
settlements of up to 1.54 inches could occur. However, because the computed
settlement occurs below a depth of 25 feet, the likelihood of significant surface
manifestation from settlement at such depth is low. Therefore, the potential for
liquefaction would be considered a less than significant impact.
a.iv) Less than Significant. Slope failures, including landslides, include many
phenomena that involve the down-slope displacement and movement of material,
either triggered by static (i.e., gravity) or dynamic (i.e., earthquake) forces. Slope
failure is dependant on degree of incline, subsurface materials, precipitation,
excavation, and seismicity. The type of failure can include deep-seated massive
slope movements or shallow slump type movements.
The project site is generally level and it is not located within an “earthquake-
induced landslide” zone according to the Seismic Hazard Zone map for the Palo
Alto Quadrangle (CGS, 2006). Therefore, the potential impact of slope failure
would be considered less than significant.
b) Less than Significant with Mitigation. Construction activities associated with the
proposed project would require earthmoving, grading, and compaction. These
activities may expose areas of soil that have previously been covered with asphalt,
Initial Study
Palo Alto High School Master Plan 57 ESA / 209002
Initial Study September 2009
concrete, or landscaping. This temporary loss of erosion control would expose bare
soil, which would be subjected to erosion by wind and storm water runoff.
Concentrated water erosion, if not managed or controlled, can eventually result in
substantial soil loss and/or discharging of sediment into utilities, adjacent lots, or
nearby creeks and drainages. Excessive soil loss can cause a potential threat to the
structural integrity of structural foundations, earthen berms, or engineered fills.
Stormwater discharges from construction activities that disturb one acre or more are
regulated by the local Regional Water Quality Control Board (RWQCB) and are
subject to the permitting requirements of the National Pollutant Discharge
Elimination System (NPDES) General Permit for Discharges of Stormwater Runoff
Associated with Construction Activity (General Construction Permit). The General
Construction Permit requires the preparation and implementation of a Storm Water
Pollution Prevention Plan (SWPPP) for construction activities.
As fully described in Checklist Item 8, Hydrology and Water Quality, Mitigation
Measure HYD-1, the PAUSD would be required to develop and implement a
SWPPP in order to minimize potential erosion and subsequent sedimentation of
storm water runoff. This SWPPP would include Best Management Practices
(BMPs) to control erosion associated with grading, trenching, and other ground
surface-disturbing activities.
Since BMPs have been recognized as methods to effectively prevent or minimize
the erosion, and the PAUSD will adhere to erosion control measures outlined in the
SWPPP, the potential for erosion impacts during the various projects would be less
than significant.
c) Less than Significant with Mitigation. The soils at the project site in the upper
five to 17-foot layer consist predominantly of stiff to very stiff sandy clay overlying
medium dense to dense clayey gravelly sand, silty gravelly sand, and poorly graded
sands and gravels to the maximum depth explored of 45 feet (Cleary, 2009). The
potential landslide hazard for the proposed project is discussed above in Section
IV.a.iv. Due to the absence of a free face in the vicinity of the relatively level site,
and the generally high relative densities associated with the subsurface soils, soil
lurching and lateral spreadings are considered unlikely (Cleary, 2009). With
implementation of preliminary foundation recommendations and Mitigation
Measure GEO-1, above, the potential hazard from unstable soils would be
considered less than significant.
d) Less than Significant with Mitigation. Preliminary foundation recommendations
indicated that the upper sandy clay at the project site is considered to be low to
moderately expansive based on its plasticity characteristics and laboratory test
results (Cleary, 2009). The effects of expansive soils could damage foundations and
aboveground structures, paved parking areas, and concrete slabs. Surface structures
with foundations constructed in expansive soils could experience expansion and
Initial Study
Palo Alto High School Master Plan 58 ESA / 209002
Initial Study September 2009
contraction depending on the season and the amount of surface water infiltration.
The expansion and contraction due to the behavior of expansive soils could exert
enough pressure on the structures to result in cracking, settlement, and uplift.
Recommendations given in geotechnical reports require design and construction of
proposed projects to follow engineering design criteria needed to improve and/or
eliminate settlement from expansive soils conditions. The design and construction
of the proposed project in accordance with the preliminary foundation
recommendation by Cleary, and implementation of Mitigation Measure GEO-1,
would ensure that the level of risk from expansive soils would be less than
significant.
e) No Impact. Implementation of the proposed project would not involve the use of
septic tanks or alternative wastewater treatment disposal systems to handle
wastewater generation. Therefore, no impact would result from project
implementation.
Sources
Association of Bay Area Governments (ABAG), Earthquake Hazard Map for Palo Alto/Stanford, Peninsula Segment of the San Andreas Fault System, www.abag.ca.gov/cgi-bin/pickmapx.pl, accessed July 20, 2009.
California Geological Survey (CGS), Probabilistic Seismic Hazards Mapping Ground Motion Page, http://redirect.conservation.ca.gov/cgs/rghm/psha/pshamap.asp, accessed July 24, 2009.
CGS, Seismic Hazard Zones, Palo Alto Quadrangle Official Map, October 18, 2006.
CGS, Special Studies Zones, Palo Alto Quadrangle Official Map, July 1, 1974.
California Public Resources Code, Division 2, Geology, Mines and Mining, Chapter 7.8, Seismic Hazards Mapping, Section 2693(c).
City of Palo Alto, Comprehensive Plan Update, 1996.
City of Palo Alto, Draft and Final Environmental Impact Report, Comprehensive Plan Update, 1996.
Cleary Consultants, Inc., Geotechnical Investigations, Campus Improvements-Group 2, Palo Alto High School, July 30, 2009.
Initial Study
Palo Alto High School Master Plan 59 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
7. Hazards and Hazardous Materials
Would the project:
a) Create a significant hazard to the public or the
environment through the routine transport, use, or
disposal of hazardous materials?
b) Create a significant hazard to the public or the
environment through reasonably foreseeable upset
and accident conditions involving the release of
hazardous materials into the environment?
c) Emit hazardous emissions or handle hazardous or
acutely hazardous materials, substances, or waste
within one-quarter mile of an existing or proposed
school?
d) Be located on a site which is included on a list of
hazardous materials sites compiled pursuant to
Government Code Section 65962.5 and, as a result,
would it create a significant hazard to the public or the
environment?
e) For a project located within an airport land use plan
or, where such a plan has not been adopted, within
two miles of a public airport or public use airport,
would the project result in a safety hazard for people
residing or working in the project area?
f) For a project within the vicinity of a private airstrip,
would the project result in a safety hazard for people
residing or working in the project area?
g) Impair implementation of or physically interfere with
an adopted emergency response plan or emergency
evacuation plan?
h) Expose people or structures to a significant risk of loss,
injury or death involving wildland fires, including where
wildlands are adjacent to urbanized areas or where
residences are intermixed with wildlands?
Setting
Hazardous materials are handled and stored on a number of properties in Palo Alto,
primarily in the East Bayshore and San Antonia Road/Bayshore corridor, University
Avenue/Downtown, the South of Forest Area, and at the Stanford Research Park.
Contamination has resulted from leaking underground storage tanks, disposal of
hazardous materials, and various industrial practices. Fuel leak sites are concentrated in
the areas of University Avenue/Downtown, South of Forest, the Stanford Research Park,
and along San Antonia Road, Alma Street, and El Camino Real.
The California Environmental Protection Agency, Department of Toxic Substances
Control (DTSC) is authorized by the United States Environmental Protection Agency
(EPA) to enforce and implement federal hazardous materials laws and regulations,
including disposal and transportation of hazardous materials.
Initial Study
Palo Alto High School Master Plan 60 ESA / 209002
Initial Study September 2009
Discussion
a, b) Less than Significant with Mitigation. The Department of Toxic Substances
Control (DTSC) EnviroStor database did not list any existing hazardous materials
sites at or in the immediate vicinity of the school (DTSC, 2009). Three leaking
underground fuel tank sites nearby have all been remediated and the cases have
been closed. The proposed project includes re-grading in areas prior to new
construction. Construction would require the use of certain hazardous materials
such as fuels, oils, solvents, and glues. Inadvertent release of large quantities of
these materials into the environment could adversely impact soil, surface waters, or
groundwater quality. However, implementation of Mitigation Measure HAZ-1
would reduce the risk associated with hazardous materials used during construction
to a less than significant level.
Mitigation Measure HAZ-1: The PAUSD shall require the use of
construction best management practices typically implemented as part of its
construction activities to minimize the potential adverse effect of the project
to groundwater and soils from construction activities. These shall include the
following:
• Follow manufacturer’s recommendations on the use, storage, and disposal of chemical products used in construction;
• Avoid overtopping construction equipment fuel tanks;
• During routine maintenance of construction equipment, properly contain and remove grease and oils; and
• Properly dispose of discarded containers of fuels and other chemicals.
c) Less than Significant with Mitigation. The project site consists of an existing high
school. As under existing conditions, proposed development on the campus,
including new classrooms, lounges, recreational facilities, and other associated
educational facilities, would involve storage and use of limited quantities of
hazardous materials such as cleaners, toners, correction fluid, paints, lubricants,
kitchen and restroom cleaners, pesticides and other maintenance materials, but not
to the extent of causing a significant impact.
Construction and renovation of the various Master Plan projects would be
completed in phases over a period of several years with some of the work scheduled
for the summer months. Considering the types and quantities of hazardous materials
used and stored, and implementation of Mitigation Measure HAZ-1, the proposed
project would not emit or use acutely hazardous materials during either construction
or operation that would significantly impact the schools or immediate area.
Initial Study
Palo Alto High School Master Plan 61 ESA / 209002
Initial Study September 2009
d) No Impact. The project site is not included on a list of hazardous materials sites
compiled pursuant to Government Code Section 65962.5; therefore, no impact
would result (DTSC, 2009).
e, f) No Impact. The project site is not located within the boundaries of the
Comprehensive Land Use Plan (CLUP) for the Palo Alto Airport or within the
vicinity of a private airstrip. No element of the proposed project would result in a
safety hazard related to air traffic.
g) Less than Significant. The proposed project would not impair implementation of,
or physically interfere with, an adopted emergency response plan or emergency
evacuation plan. Please also refer to Checklist Item 15, Traffic and Transportation
for additional discussion of emergency access.
h) No Impact. The project site is located in an urbanized area and is not intermixed
with or adjacent to wildlands. There are no elements of the proposed project that
would increase the potential for wildfires in the project vicinity. All new buildings
would be required to comply with all applicable fire code and fire suppression
systems, and be approved by the Division of State Architect for fire and life-safety
compliance. Therefore, the proposed project would not expose people or structures
to significant risks associated with wildland fires.
Sources
California Department of Toxic Substances Control (DTSC), EnviroStor Database, www.envirostor.dtsc.ca.gov, accessed July 21, 2009.
City of Palo Alto, Comprehensive Plan Update, 1996.
City of Palo Alto, Draft and Final Environmental Impact Report, Comprehensive Plan Update, 1996.
County of Santa Clara, Comprehensive Airport Land Use Plan, Palo Alto Airport, adopted November 19, 2008.
County of Santa Clara, Wildland Urban Interface Fire Area Map, February 24, 2009.
Initial Study
Palo Alto High School Master Plan 62 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
8. Hydrology and Water Quality
Would the project:
a) Violate any water quality standards or waste
discharge requirements?
b) Substantially deplete groundwater supplies or interfere
substantially with groundwater recharge such that there would be a net deficit in aquifer volume or a lowering of the local groundwater table level (e.g., the production
rate of pre-existing nearby wells would drop to a level
which would not support existing land uses or planned
uses for which permits have been granted)?
c) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the
course of a stream or river, in a manner which would
result in substantial erosion of siltation on- or off-site?
d) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river, or substantially increase the
rate or amount of surface runoff in a manner which
would result in flooding on- or off-site?
e) Create or contribute runoff water which would exceed the capacity of existing or planned stormwater drainage systems or provide substantial additional
sources of polluted runoff?
f) Otherwise substantially degrade water quality?
g) Place housing within a 100-year flood hazard area as
mapped on a federal Flood Hazard Boundary or Flood
Insurance Rate Map or other flood hazard delineation
map?
h) Place within a 100-year flood hazard area structures which would impede or redirect flood flows?
i) Expose people or structures to a significant risk of
loss, injury or death involving flooding, including
flooding as a result of the failure of a levee or dam?
j) Inundation of seiche, tsunami, or mudflow?
Setting
The City of Palo Alto is located in the watersheds of several creeks and drainageways,
including Adobe, Barron, Matadero, and San Francisquito Creeks. The Santa Clara
Valley Water District regulates creekside development and provides flood control
services in the City of Palo Alto. Barron Creek begins in the foothills of Los Alto Hills
and flows northwest through Palo Alto until it joins Adobe Creek just west U.S. 101.
Barron Creek is in a relatively natural state southwest of the project site. A flood control
project was completed in 1996 that diverts excess flows from the creek into Matadero
Creek during large storm events. Barron Creek flows in an underground culvert across
the project site beginning at a Santa Clara Valley Water District retention basin on the
western boundary of the campus.
Initial Study
Palo Alto High School Master Plan 63 ESA / 209002
Initial Study September 2009
Most of the urban core of Palo Alto is located within the Federal Emergency
Management Agency (FEMA) Flood Zone X. These areas are outside the 100-year flood
zone, but within the 500-year flood zone. Some areas are located within Special Flood
Hazard Areas, which are subject to flooding in the event of a 100-year flood.
Groundwater in Palo Alto is contained in both shallow and deep aquifers formed in the
alluvial deposits of streams running from the foothills to San Francisco Bay. Historical
saltwater intrusion in the shallow aquifers along the bay has largely been reversed as
alternative sources of water have been secured for irrigation and other purposes. Surface
water bodies in and around the City include Felt, Searsville, Boronda, and Arastradero
Lakes and the Lagunita Reservoir.
Discussion
a) Less than Significant with Mitigation. The proposed project could result in
potential water quality impacts during construction phases. Construction activities
involving soil disturbance, excavation, cutting/filling, stockpiling, and grading
activities could result in increased erosion and sedimentation to surface waters,
which could produce contaminated stormwater runoff, a major contributor to the
degradation of water quality.
Project construction would also involve use of motorized heavy equipment,
including trucks and other construction vehicles that require fuel, lubricating grease,
and other fluids. Accidental chemical release or spill from a vehicle or equipment
could affect surface water. Such spills could also wash into nearby storm drains or
infiltrate into soil affecting groundwater quality. However, the volume of material
would not be significant; therefore runoff and groundwater pollution resulting from
use of construction vehicles is considered minimal. Furthermore, implementation of
standard construction procedures and precautions as discussed under Section 7,
Hazards and Hazardous Materials, would ensure that impacts related to construction
vehicle pollutants would be less than significant.
The NPDES permit program under the Federal Clean Water Act controls water
pollution by regulating point and nonpoint sources that discharge pollutants into
“waters of the U.S.” Authority for NPDES permitting has been delegated by the
federal government to the California State Water Resources Control Board
(SWRCB), which has nine regional boards; the San Francisco Bay Regional Water
Quality Control Board (RWQCB) regulates water quality in the project area.
The Santa Clara Valley Urban Runoff Pollution Prevention Program (SCVURPPP)
is an association of thirteen cities and towns in the Santa Clara Valley (including
Palo Alto), together with Santa Clara County and the Santa Clara Valley Water
District. Program participants share a common permit to discharge stormwater to
South San Francisco Bay. The RWQCB issued the SCVURPPP its first NPDES
permit in 1990, and reissued the permit in 1995. In 2001, the SCVURPPP was
reissued its third NPDES permit and provision C.3 of the permit was also revised to
Initial Study
Palo Alto High School Master Plan 64 ESA / 209002
Initial Study September 2009
address post-construction and some construction phase impacts of new and
redevelopment projects on stormwater quality.
Provision C.3 calls for enhancement of the existing performance standard to
increase the effectiveness of existing implementation, primarily by: 1) setting
volume and flow based hydraulic sizing criteria for stormwater treatment measures;
2) setting minimum sizes of new development and redevelopment projects which
must employ the treatment measures; 3) creation of a program to assure the
adequate operation and maintenance of treatment measures occurs; 4) creation of
standards for source control measures and site design measures which can lead to
reduced impervious surface for a given equivalent land use; and 5) development of
a process and criteria to limit changes in the runoff hydrograph for new and
redevelopment, where those changes could have a harmful effect on downstream
beneficial uses by excessive erosion of the bed and bank of downstream
watercourses.
Stormwater discharges from construction activities on one acre or more are
regulated by the RWQCB and are subject to the permitting requirements of the
NPDES General Permit for Discharges of Stormwater Runoff Associated with
Construction Activity (General Construction Permit). The General Construction
Permit requires the preparation and implementation of a SWPPP for construction
activities. As described in Section 6, Geology and Soils, above, the SWPPP must be
prepared before the construction begins, and in certain cases, before demolition
begins. The SWPPP must include specifications for BMPs that would need to be
implemented during project construction. BMPs are measures that are undertaken to
control degradation of surface water by preventing soil erosion or the discharge of
pollutants from the construction area. The SWPPP must describe measures to
prevent or control runoff after construction is complete and identify procedures for
inspecting and maintaining facilities or other project elements.
The proposed project would disturb approximately 1.6 acres (DLM, 2009),
exceeding the NPDES one-acre threshold; therefore, the PAUSD would be required
to apply to the RWQCB for the General Construction Permit and comply with the
SCVURPPP NPDES requirements that apply to “significant redevelopment”
projects. Implementation of a SWPPP, as required by Mitigation Measure HYD-1,
would ensure that the proposed project would not violate any water quality
standards or waste discharge requirements and reduce potential impacts to a less
than significant level.
Mitigation Measure HYD-1: The PAUSD shall apply for coverage under the
State General Construction Permit to comply with federal NPDES regulations.
The NPDES and State General Construction Permit require a project applicant
to develop and implement a Storm Water Pollution Prevention Plan (SWPPP)
that identifies appropriate construction BMPs in order to minimize potential
sedimentation or contamination of storm water runoff generated from the
Initial Study
Palo Alto High School Master Plan 65 ESA / 209002
Initial Study September 2009
project site. BMPs could include, without limitation, silt fences, gravel or sand
bag berms, storm drain inlet protection, soil stockpile protection, preservation
of existing vegetation, use of straw mulch, dust control, and others. The
SWPPP shall also include any additional measures identified in the Santa
Clara Valley Urban Runoff Pollution Prevention Program, as required. The
project sponsor shall adhere to the identified BMPs as well as the waste
discharge and stormwater requirements outlined in the permit.
b) Less than Significant. Preliminary geotechnical investigation of the project site indicated
that the uppers soils are considered unsuitable for proposed building foundations and slabs
and would require excavation and replacement with engineered fill to a depth of at least
3.0 feet below the ground surface (see Section 6, Geology and Soils). The water level was
encountered in borings at depths of 25 to 30 feet. Therefore, the potential for intercepting
groundwater and depleting groundwater supplies or recharge through excavation or
subsurface foundations is considered to be low. Water supply to the City of Palo Alto is
provided by the City Utilities Department through purchases from the San Francisco Public
Utilities Commission’s Hetch Hetchy water supply system. The proposed project would not
involve depletion of groundwater supplies; however, it would increase the amount of
impervious surface area and thereby reduce the potential amount of groundwater recharge.
As mentioned above, the proposed project would have to comply with the C.3
requirements, which include measures for reducing the amount of flow from off-site and
using biofiltration improvements to the extent possible. Adherence to these requirements
would reduce the amount of off-site runoff volumes and create a less than significant
impact to groundwater supplies.
c, d) Less than Significant with Mitigation. Proposed new structures and other
improvements on the project site would not alter existing drainage patterns, nor
would there be any alteration of the existing Santa Clara Valley Water District
retention basin located on the western boundary of the campus. Although soil
erosion could occur due to project construction, the resulting operational surface
runoff rates would not significantly increase due to the generally flat topography of
the project site and the relatively small net increase in impervious surface areas
occurring during each individual phase of the Master Plan. The potential for
accelerated runoff flow rates or flooding would be low. The use of BMPs and
adherence to SWPPP and NPDES permit requirements as described in Mitigation
Measure HYD-1, above, would reduce potential erosion and flooding impacts to a
less than significant level.
e) Less than Significant with Mitigation. As discussed above, the surface runoff
rates resulting from operation of individual phases of the Master Plan would not
significantly increase due to the generally flat topography of the project site and the
relatively small net increase in impervious surface area. Stormwater runoff would
flow from the project site into the City of Palo Alto’s stormwater drainage system,
which would be adequate to handle any increase in flows resulting from the
proposed project. In addition, stormwater treatment measures required as part of the
Initial Study
Palo Alto High School Master Plan 66 ESA / 209002
Initial Study September 2009
NPDES permit described above in Mitigation Measure HYD-1, including, but not
limited to, vegetated swales, detention basins, and landscape infiltration systems,
must be hydraulically sized to treat a specified amount of runoff, and they must
include provisions to meet ongoing maintenance needs. Therefore, the project’s
impact on the stormwater drainage system would be less than significant.
f) Less than Significant with Mitigation. As discussed in a) and c) above,
construction is the only phase of the proposed project that could affect water
quality. Stormwater runoff would be controlled on-site using standard engineering
practices and as required by Mitigation Measure HYD-1. Therefore, substantial
degradation of water quality would not be expected and the proposed project’s
impact would be less than significant.
g, h) Less than Significant. According to the FEMA Flood Insurance Rate Maps
covering the project area, the Paly campus is located within Flood Zone X. This
area is outside the 100-year flood zone; therefore, the impact would be considered
less than significant.
i) Less Than Significant. The 2003 Flood Inundation Maps prepared by the Santa
Clara Valley Water District indicated that the project site would not be subject to
inundation in the event of a failure of the Stevens Creek Dam, Lexington Dam,
Anderson Dam, Coyote Percolation Dam, Riconada T. W. Reservoir, or the Vasona
Dam (Cleary, 2009). Therefore, the risk of inundation through failure of a levee or a
dam would be less than significant at the project site.
j) No Impact. Although tsunamis could occur and cause tidal surges in San Francisco
Bay, these events are extremely rare and the project site is located sufficiently far
enough away from the Bay shoreline that tsunamis would not impact the project
site. The project site is outside of the runup zone resulting from a seismically
generated tsumani with a 20-foot runup at the Golden Gate (Cleary, 2009).No water
bodies large enough to cause a seiche are located in the vicinity of the project site.
The potential for mudflows or landslides is discussed under Section 6, Geology and
Soils. No impact would occur due to inundation of seiche or tsunami.
Sources
City of Palo Alto, Comprehensive Plan Update, 1996.
City of Palo Alto, Draft and Final Environmental Impact Report, Comprehensive Plan Update, 1996.
Cleary Consultants, Inc., Geotechnical Investigations, Campus Improvements-Group 2, Palo Alto High School, July 30, 2009.
Deems Lewis McKinley, Palo Alto High School, Site Perviousness, 2009.
Federal Emergency Management Agency (FEMA), Flood Insurance Rate Map (FIRM), Santa Clara County, Map Numbers 06085C0010H, 06085C0016H, and 06085C0017H, May 18, 2009.
Initial Study
Palo Alto High School Master Plan 67 ESA / 209002
Initial Study September 2009
Santa Clara Valley Urban Runoff Pollution Prevention Program, www.scvurppp-
wk2.com, accessed July 14, 2009.
Initial Study
Palo Alto High School Master Plan 68 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
9. Land Use and Planning
Would the project:
a) Physically divide an established community?
b) Conflict with any applicable land use plan, policy, or
regulation of an agency with jurisdiction over the
project (including, but not limited to the general plan,
specific plan, local coastal program, or zoning
ordinance) adopted for the purpose of avoiding or
mitigating an environmental effect?
c) Conflict with any applicable habitat conservation plan
or natural community conservation plan?
Setting
The Paly campus is located on an approximately 44-acre site southeast of the El Camino
Real and Embarcadero Road intersection. The campus is owned and occupied by the
PAUSD, but the site has a reversionary clause to Stanford University on 26 acres.
Original construction began in 1918 and approximately 17 buildings currently exist on
the campus. Adjacent land uses include residential areas to the east and southeast,
Stanford University to the west, and the Town and Country Village shopping center to
the north.
Local Plans and Policies
The following policies from the Land Use and Community Design Element and the
Community Services and Facilities Element of the City of Palo Alto Comprehensive Plan
are relevant to the proposed project:
Policy L-5: Maintain the scale and character of the City. Avoid land uses that are overwhelming and unacceptable due to their size and scale.
Policy L-7: Evaluate changes in land use in the context of regional needs, overall City welfare and objectives, as well as the desires of surrounding neighborhoods.
Policy L-48: Promote high quality, creative design and site planning that is compatible with surrounding development and public spaces.
Policy L-61: Promote the use of community and cultural centers, libraries, local schools, parks, and other community facilities as gathering places. Ensure that they are inviting and safe places that can deliver a variety of community services during both daytime and evening hours.
Policy L-71: Strengthen the identity of important community gateways, including entrances to the City at … Embarcadero Road at El Camino Real.
Policy C-4: Maintain a close, collaborative relationship with the PAUSD to maximize the use of school services and facilities for public benefit, particularly for young people, families, and seniors.
Initial Study
Palo Alto High School Master Plan 69 ESA / 209002
Initial Study September 2009
Policy C-5: Recognize the importance of schools to the social and economic vitality of
the City.
Policy C-6: Continue and enhance City efforts to assist PAUSD in anticipating and
addressing land development-related school enrollment impacts.
The General Plan designates the project site as School District Lands. This land use
designation applies to properties owned or leased by public school districts and used for
educational, recreational, or other non-commercial, non-industrial purposes. Floor area
ratio may not exceed 1.0. The campus is zoned PF-Public Facilities, which is designed to
accommodate governmental, public utility, educational, and community service or
recreational facilities.
The California Constitution (Article 9, Section 6), prohibits the PAUSD, as a component
of the state’s public school system, from being placed under the jurisdiction of a local
government. Therefore, PAUSD is exempt from the requirement to comply with local
land use controls, including local general plans and zoning ordinances, within the
District’s boundaries. However, the PAUSD attempts to ensure its Master Plan is
compatible with the goals and policies of the City of Palo Alto to the extent feasible.
Goals of the Master Plan are listed below:
• Give organization and structure to the campus
• Create a hierarchy of open space
• Utilize in-between spaces—preserve open space
• Create edges to open space and buildings
• Define and articulate building entries
• Provide growth strategies—consolidate departmental functions
Discussion
a, b) Less Than Significant. The land uses proposed as part of the Master Plan would
represent a continuation of established public education land uses that have existed
on the project site for several decades. The project therefore would not deviate from
established development patterns on the project site or in their vicinity. New
development would be designed in keeping with the predominant styles of the
existing campus architecture. As such, the new uses proposed as part of the project
would be consistent with, and would represent an enhancement of, existing
educational uses on the Paly campus.
While the proposed Master Plan would represent changes to the existing campus,
the proposed project would not cause a significant adverse land use impact.
Furthermore, all potential physical environmental effects of the proposed project on
adjacent land uses during construction (including traffic, noise, air quality) are
addressed and mitigated where required to the extent feasible throughout this
environmental document.
Initial Study
Palo Alto High School Master Plan 70 ESA / 209002
Initial Study September 2009
The campus improvements and educational uses proposed as part of the project
would not substantially conflict with the goals and policies in the City of Palo Alto
Comprehensive Plan. Moreover, although not bound by local land use ordinances,
project components proposed by the PAUSD would nonetheless be consistent with
the land use designation and zoning for the campus.
Moreover, the project would require review and approval by Board of Education
and would be required to meet design criteria established by the Department of
General Services, Division of the State Architect, which is responsible for review of
the architectural plans and construction documents.
In conclusion, the proposed project would not disrupt or divide the physical
arrangements of existing uses and activities that surround them, nor would the
proposed physical changes displace any businesses, residences, or other uses.
Therefore, land use impacts are considered less than significant and no mitigation is
required.
c) No Impact. As discussed in Section 4, Biological Resources, no Habitat
Conservation Plan, Natural Community Conservation Plan, or other approved local,
regional, or state habitat conservation plan exist within the project boundaries.
Sources
City of Palo Alto, Comprehensive Plan Update, 1996.
Initial Study
Palo Alto High School Master Plan 71 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
10. Mineral Resources
Would the project:
a) Result in the loss of availability of a known mineral
resource that would be of value to the region and the
residents of the state?
b) Result in the loss of availability of a locally-important
mineral resource recovery site delineated on a local
general plan, specific plan or other land use plan?
Discussion
a, b) No Impact. According to the Santa Clara County General Plan, the project site
does not contain any known mineral resources. No impact would result.
Sources
Santa Clara County, General Plan 1995-2010, adopted December 20, 1994.
Initial Study
Palo Alto High School Master Plan 72 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
11. Noise
Would the project result in:
a) Expose persons to or generate noise levels in excess
of standards established in the local general plan or
noise ordinance, or applicable standards of other
agencies?
b) Exposure of persons to or generation of excessive
groundborne vibration or groundborne vibration
levels?
c) A substantial permanent increase in ambient noise
levels in the project vicinity above levels existing
without the project?
d) A substantial temporary or periodic increase in
ambient noise levels in the project vicinity above
levels existing without the project?
e) For a project located within an airport land use plan
or, where such a plan has not been adopted, within
two miles of a public airport or public use airport,
would the project expose people residing or working in
the project area to excessive noise levels?
f) For a project within the vicinity of a private airstrip,
would the project expose people residing or working in
the project area to excessive noise levels?
Discussion
a) Less Than Significant with Mitigation. The California Department of Education
(CDE) requires all school districts to select school sites that provide safety and
support learning.13 Because the CDE recognizes that unwanted sound can be
distracting and can present an obstacle to learning, the CDE requires school districts
to consider noise in the site selection process.14 The School Site Selection and
Approval Guide document recommends that this be accomplished with an
assessment of noise from major roadways and railroads during environmental
review of school construction.15 If PAUSD considers a potential school site near a
freeway or other source of noise, CDE recommends hiring an acoustical engineer to
determine the level of sound that the location is subjected to and to assist in
designing the school. The American Speech Language-Hearing Association
(ASLHA) guidelines recommend that in classrooms, sounds dissipate in 0.4
seconds or less (and not reverberate) and that background noise not rise above 30
dBA.16 While PAUSD has not adopted any specific interior noise standard for its
13 California Department of Education (CDE), Regulations (CCR Tit. 5, Div. 1, Ch. 13 Subchapter 1, Article 2
§14010 “Standards for School Site Selection”)
14 CDE Regulations (CCR Tit. 5, Div. 1, Ch. 13 §14010(q)).
15 CDE, School Facilities Planning Division, School Site Selection and Approval Guide, March, 2001.
16 Ibid.
Initial Study
Palo Alto High School Master Plan 73 ESA / 209002
Initial Study September 2009
classrooms, other districts, such as Los Angeles Unified have adopted an interior
standard of 45 dBA.
Long-term (24-hour) noise monitoring was conducted at two locations on the Paly
campus to determine the existing noise environment of proposed locations of new
classrooms.
The first location monitored was the location of the proposed Group 2, two-story
27-room classroom building. Noise sources in this area are dominated by vehicle
traffic on Alma Street, which is approximately 200 feet from the eastern building
façade and intermittent train pass-by events on the Caltrain tracks that are
approximately 130 feet from the eastern building façade. Daytime hourly average
noise levels at this location ranged from 60 to 67 dBA with a (logarithmic) average
of 64 dBA. Maximum (instantaneous) noise levels during train pass-by events
ranged from 80 to 88 dBA, depending on the direction of the train.
The second location monitored was the location of the proposed Group 2, Media
Arts Center. Noise sources in this area are dominated by vehicle traffic on
Embarcadero Road, which is approximately 110 feet from the northern building
façade and intermittent train pass-by events on the Caltrain tracks that are
approximately 260 feet from the eastern building façade. Daytime hourly average
noise levels at this location ranged from 60 to 64 dBA with a (logarithmic) average
of 61 dBA. Maximum (instantaneous) noise levels during train pass-by events
ranged from 75 to 80 dBA, depending on the direction of the train.
Standard building construction methods typically result in a exterior to interior
noise reduction of 15 to 20 dBA (HUD, 2004), which would be insufficient to meet
the recommended goals of the ASLHA or the generally accepted 45 dBA standard
for interior residential spaces. Consequently, these two classroom buildings would
need to be designed to incorporate sound insulation sufficient to maintain interior
noise levels appropriate for a classroom.
Mitigation Measure NOI-1: The PAUSD shall collaborate with a certified
acoustical engineer to assist in design and verification of noise insulation
measures for the classrooms proposed under the Master Plan.
b) Less Than Significant with Mitigation. In discussing whether the project would
expose people to severe noise via airborne or ground-borne vibrations, this analysis
examines the impact of construction and operational activities associated with the
project on the existing sensitive receptors in the vicinity of the site as well as the
impact of the existing vibration environment on the future occupants of project
classrooms.
Ground-borne vibration from activities that involve “impact tools,” especially pile
driving could produce significant vibration. It is unknown, at the Master Plan level,
Initial Study
Palo Alto High School Master Plan 74 ESA / 209002
Initial Study September 2009
whether pile driving would be required for two-story classroom buildings to meet
seismic code. Pile driving can result in typical peak particle velocities (PPV) of
0.64 inches per second at a distance of 25 feet, which would exceed the criteria
published by the U.S. Department of Transportation (DOT) of 0.2 inches per
second for the protection of non-engineered timber and masonry buildings and 0.3
inches per second for concrete and masonry buildings with no plaster. Distances of
55 and 42 feet are required for the attenuation of pile driving vibrations to below
these respective building protection thresholds. The nearest existing buildings to the
proposed building locations are adjacent language classrooms, approximately 30
feet away. The nearest residences would be located over 200 feet away from the
proposed building locations and would not be susceptible to building damage from
pile driving activity. Consequently, the potential for adjacent building damage
would be a concern at the nearest adjacent classrooms if installation of piles were a
necessary construction method and mitigation measures are recommended.
Vibration levels can also result in interference or annoyance impacts to residences
or other land uses where people sleep, such as hotels and hospitals. Vibration
annoyance impact criteria published by U.S. DOT relative to daytime residential
land uses (the most applicable use listed to a classroom) are established in terms of
vibration decibels (VdB). VdBs are generally used when evaluating human
response to vibrations, as opposed to structural damage, where PPV is the more
commonly used descriptor. Vibration decibels are established relative to a reference
quantity, typically 1 x 10-6 inches per second.17
The criterion for vibration annoyance established by U.S. DOT for daytime
residential uses (again, the most applicable use listed to a classroom) is 78 VdB.
Pile driving can result in typical vibrations of 104 Vdb at a distance of 25 feet. The
residence nearest to the proposed two-story classrooms would be located
approximately 20 feet away at which distance vibrations from pile driving activities
would be reduced to 77 Vdb. This would be a less than significant vibration impact
to the nearest residences. However, annoyance impacts would be a concern at the
nearest adjacent classrooms if installation of piles were a necessary construction
method and mitigation measures are recommended.
Operational Vibration Impacts from Caltrain
The proposed two-story 27-room classroom building and the proposed Media Arts
Center would be located 130 feet and 260 feet, respectively, from active railroad
tracks operated by Caltrain. Based on the published Caltrain schedule (dated March
2, 2009), 98 Caltrain passenger train pass the site each weekday. Survey of
monitored vibration levels adjacent to the Caltrain tracks undertaken for the City of
San Carlos in 2006 indicates that peak vibration levels monitored at a distance of 65
feet from the southbound track and 80 feet from the northbound track were
recorded to be 72 Vdb (Illingworth and Rodkin, 2006). This would be a less than
17 Ibid.
Initial Study
Palo Alto High School Master Plan 75 ESA / 209002
Initial Study September 2009
significant vibration annoyance impact to the nearest classrooms, which are located
twice this distance from the tracks. Consequently, annoyance impacts to students at
the propose classrooms nearest the Caltrain tracks would be less than significant.
To reduce potential structural damage impacts from pile driving (if necessary) on
nearby existing and/or future buildings, PAUSD shall implement Mitigation
Measures NOI-2 and NOI-3:
Mitigation Measure NOI-2:
• Verify the construction method of adjacent buildings of concern. If
buildings are constructed of reinforced concrete, steel or timber without
plaster, these structures can withstand vibrations of up to 0.5 PPV
without structural damage. If located at a distance of at least 30 feet
from pile locations potential structural impacts would be considered less
than significant.
• Use alternative driving methods. If adjacent buildings are non-
engineered timber and masonry buildings or concrete and masonry
buildings with no plaster then alternative driving methods may be
employed to reduce vibration impacts to a less than significant level.
Use of a sonic (or vibratory) pile driver can result in typical vibration
levels being reduced from 0.644 feet per second to 0.170 feet per second
(U.S. DOT, 2006). Alternatively pile holes may be pre-drilled to reduce
vibrations.
Mitigation Measure NOI-3: To reduce the potential for annoyance impacts
from pile driving (if necessary) at occupied adjacent classrooms, PAUSD
shall have the contractor schedule any pile driving activities during the
summer or winter breaks or other times when classrooms within a 150-foot
radius are unoccupied. Additionally, any required pile driving should be
restricted to daytime hours.
c) Less Than Significant. Future development of the site could generate noise from
motor vehicle trips as well as from stationary sources (i.e., HVAC equipment etc.)
that could adversely affect nearby noise-sensitive land uses.
Noise from air handling equipment would be located more than 200 feet away from
the nearest sensitive receptor and would be no different than the existing equipment
located on campus buildings. Given the presence of other noise sources between the
site and the nearest residential receptors (Caltrain and Alma Street), noise from air
handling equipment would not represent a significant noise impact.
Noise level projections from roadway traffic increases were made using traffic data
and the TNM version 2.5 Lookup Noise Prediction Model of the Federal Highway
Administration (FHWA) for those road segments that would experience the greatest
increase in traffic volumes and/or that would pass nearest to residential areas. The
Initial Study
Palo Alto High School Master Plan 76 ESA / 209002
Initial Study September 2009
model is based on the TNM reference noise factors for automobiles, medium trucks,
heavy trucks, and buses with consideration given to vehicle volume, speed,
roadway configuration, and distance to the receiver.
The results of the modeling are shown in Table 2 for existing, existing plus project
and 2018 plus project scenarios. The traffic analysis indicates that the proposed
project would generate approximately 886 total daily vehicle trips. This traffic
would be distributed over the local street network and would affect roadside noise
levels. For the modeling effort, a.m. peak hour traffic volumes during weekdays
were used as a worst-case analysis because the proposed project would contribute
more traffic to the a.m. peak hour than to the a.m. peak hour. Modeled existing
noise levels shown in Table 2 correspond to a distance of 50 feet from the
centerline of applicable roadway segments.
TABLE 2
TRAFFIC NOISE INCREASES IN ROADSIDE LEQ
Road Segment Existing
Existing +
Project
Contribution of
Proposed
Project
Modeled
Cumulative Year
2018 with
Proposed Project
Modeled Cumulative
Incremental Increase
2009 vs 2018
with Proposed
Project)
1. Embarcadero Road
(between Kingsley
Avenue and Paly
Driveway)
62.9 63.1 0.2 64.2 1.3
2. El Camino Real (between Churchill
Avenue and
Embarcadero Road)
69.3 69.3 0.0 70.1 0.8
3. Churchill Avenue
(between Paly Driveway and El
Camino Real)
59.8 59.9 0.1 60.0 0.2
4. Churchill Avenue
(between Emerson
Street and Alma Street)
57.1 57.2 0.1 59.4 1.3
5 Alma Street (between
Kellogg Avenue and
Churchill Avenue)
68.7 68.7 0.0 67.5 - 1.2b
6. Alma Street (between
Coleridge Avenue and Churchill Avenue)
69.4 69.4 0.0 68.7 - 0.7b
a These listed values represent the modeled existing noise levels from mobile sources along specified roadways and are based on traffic
data. Road center to receptor distance is assumed to be 50 feet. The speed limit for these segments is assumed to be 25 miles per hour
except foe El Camino Real and Alma Streets for which the assumed speed was 35 miles per hour.
b A decrease in noise is predicted at these segments because traffic projections predict a decrease in northbound roadway volumes by 2018. SOURCE: ESA, 2009.
Initial Study
Palo Alto High School Master Plan 77 ESA / 209002
Initial Study September 2009
As can be seen from the data in Table 2, roadway traffic noise increases resulting
from the proposed project would be less than 1 dBA. Generally, even in a
laboratory environment, increases of less than 1 dBA are too small to be detected
by the human ear (Caltrans, 1998). Consequently, increases in roadway noise
resulting from the proposed project would be less than significant.
d) Less than Significant with Mitigation. Noise standards are typically addressed in
Title 24, local General Plan policies and local noise ordinance standards. The City
of Palo Alto Noise Ordinance (Section 9.10.060 of the Municipal Code) establishes
construction noise regulations in the City. The noise ordinance restricts the
allowable hours for construction to between 8:00 a.m. and 6:00 p.m. on weekdays.
Construction may occur on weekends between 9:00 a.m. and 5:00 p.m. on
Saturdays. Construction activities are prohibited on Sundays and holidays. In
addition, no individual pieces of construction equipment are allowed to exceed 110
dBA at a distance of 25 feet.
Construction of future buildings would involve demolition of some existing
structures at the site and the construction of one and two-story classrooms,
renovations of existing buildings and improvements to athletic fields involving
earthwork. Various types of equipment would be used for demolition and
construction purposes. Some of this equipment would generate relatively steady-
state noise levels, such as the noise from diesel engines, and other equipment would
generate impulse or impact noise.
Construction noise levels at and near locations on the project site would fluctuate
depending on the particular type, number, and duration of use of various types of
construction equipment. The effect of construction noise depends upon how much
noise would be generated by construction, the distance between construction
activities and the nearest noise-sensitive uses, and the existing noise levels at those
uses.
Table 3 shows typical noise levels generated by construction equipment. As shown
in Table 3, the noisiest phases of (non-pile driving) construction would generate
approximately 88 Leq at 50 feet. Pile driving, if necessary, would generate noise
levels of approximately 101 dBA at 50 feet. All of these construction equipment
noise levels would be consistent with the restriction of the City’s municipal code.
The receptors nearest to the proposed construction activities would be adjacent
classrooms. The nearest residences to proposed construction activities would be
located 200 feet from the proposed two-story classroom, across Alma Street and
residences across Churchill Avenue, approximately 120 feet from proposed
earthwork for renovation of the baseball and softball fields.
Initial Study
Palo Alto High School Master Plan 78 ESA / 209002
Initial Study September 2009
TABLE 3
TYPICAL CONSTRUCTION EQUIPMENT NOISE EMISSION LEVELS
Equipment Noise Level (Leq)a
Shovel (Excavator) 82
Back Hoe 80
Concrete pumps 82
Jack Hammer 88
Pneumatic tools 85
Truck 88
Pile Driving 101
a Estimates correspond to a distance of 50 feet from the piece of equipment.
SOURCE: U.S. Department of Transportation, Transit Noise and Vibration Impact Assessment, May 2006.
While construction-related noise would be within the limits established by the
City’s noise ordinance, construction noise could be a nuisance to the nearest
sensitive receptors. Consequently, mitigation measures are recommended to reduce
noise impacts of project construction on adjacent sensitive receptors.
Mitigation Measure NOI-4: Construction contractors shall be required to
follow appropriate time restrictions consistent with the City’s Municipal
Code. Specifically, it is recommended that contractors be required to limit
noisy construction activities, including related on-road truck use in the
immediate project vicinity, to the hours of 8:00 a.m. to 6:00 p.m. on
weekdays. No construction shall be allowed on Sundays and legal holidays. In
addition, although not required, it is recommended that the use of impact tools
(e.g., hoe-ram, jackhammers, pile driver) be limited to the hours of 8:00 a.m.
to 5:00 p.m.
Construction Related Noise Attenuation Measures
• Notify adjacent residents of any planned pile-driving activities, as well
as any particularly noisy activity that would affect them for a given short
period of time so they can plan their activities accordingly.
• Ensure that all diesel equipment is equipped with effective mufflers, in
accordance with the manufacturer’s specifications, and that the mufflers
are in good repair.
• Use temporary noise barriers along the perimeter of the sites, to the
maximum extent feasible during demolition and grading activities.
• Locate stationary noise-generating equipment such as generators and
compressors as far as possible from the nearest residential property line.
Initial Study
Palo Alto High School Master Plan 79 ESA / 209002
Initial Study September 2009
• Locate any construction trailers or offices as far from the adjacent
residential uses as possible.
Implementation of the above mitigation measures would reduce the impact to less than
significant levels.
e, f) No Impact. There are no public use airports or private air strips within a two mile
radius of the project site. Consequently, there are no noise or vibration impacts
associated with these uses that would occur on the project site.
Sources
Illingworth and Rodkin, San Carlos Train Depot Site, Noise and Vibration Assessment San Carlos, California, August 8, 2006.
U.S. Department of Transportation, Federal Traffic Administration (FTA), Transit Noise and Vibration Impact Assessment, May 2006.
U.S. Department of Housing and Urban Development, Office of Community Planning and Development, The Noise Guidebook, updated, August, 2004.
Initial Study
Palo Alto High School Master Plan 80 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
12. Population and Housing
Would the project:
a) Induce substantial population growth in an area, either
directly (for example, by proposing new homes and
businesses) or indirectly (for example, through
extension of roads or other infrastructure)?
b) Displace substantial numbers of existing housing,
necessitating the construction of replacement housing
elsewhere?
c) Displace substantial numbers of people, necessitating
the construction of replacement housing elsewhere?
Discussion
a) Less than Significant. As described in the Project Description, the purpose of the
proposed project is to renovate existing aging facilities, and to provide additional
building capacity, as well as various infrastructure and site
access/circulation/landscaping upgrades consistent with the Master Plan. Student
enrollment is anticipated to incrementally increase within the PAUSD over the time
period of the Master Plan buildout in 2017. However, the proposed project would
not, in itself, induce student growth within the PAUSD, but rather, better
accommodate existing and planned student enrollment within the PAUSD.
Furthermore, utility infrastructure improvements are intended to improve utility
service at the project site, and would not be oversized to potentially serve additional
growth within the area.
b, c) Less than Significant. The proposed project would not displace any existing
housing or generate a demand for housing elsewhere. Furthermore, the project
would not result in a displacement of people from the project site. No impact would
result.
Sources
PAUSD, Palo Alto High School Master Plan, 2009.
Lapkoff & Gobalet Demographic Research, Inc., Enrollment Forecasts for PAUSD Middle and High Schools, January 12, 2009.
Initial Study
Palo Alto High School Master Plan 81 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
13. Public Services
Would the project:
a) Result in substantial adverse physical impacts
associated with the provision of new or physically
altered governmental facilities, need for new or
physically altered governmental facilities, the
construction of which could cause significant
environmental impacts, in order to maintain
acceptable service ratios, response times, or other
performance objectives for any of the public services:
Fire protection?
Police protection?
Schools?
Parks? – See Section 14
Other public facilities?
Setting
Fire Protection Services
Fire protection services to the project site are provided by the City of Palo Alto Fire
Department. The Fire Department has approximately 122 employees and staffs seven
full-time stations located throughout the City and on the Stanford University campus. To
provide coverage in the sparsely developed hillside areas, an additional fire station in the
foothills is operated during summer months when fire danger is high. Service areas for
the Fire Department include the Stanford University campus, the Stanford Linear
Accelerator Center (SLAC), and unincorporated areas of Santa Clara County. The nearest
fire station to the Paly campus is Fire Station No. 1 at 301 Alma Street, which is
approximately one-mile from the campus. The City also has mutual aid agreements with
Menlo Park, Mountain View, Los Altos, and Woodside.
In fiscal year 2007-08, the Fire Department responded to an average of 21 calls per day.
The average response time for fire calls was 6 minutes 48 seconds, and the average
response time for medical/rescue calls was 5 minutes 24 seconds. There were more than
4,500 medical/rescue incidents and 192 fire incidents (including 43 residential structure
fires) in 2007-2008. The Fire Department also performed 1,277 fire inspections and 406
hazardous materials inspections.
Police Protection Services
Law enforcement services to the project site are provided by the Palo Alto Police
Department. The Police Department has 169 personnel; it shares Special Weapons and
Tactical (SWAT) Teams with Los Altos and Mountain View and provides dispatching to
the Stanford University Police through the City’s Communications Center.
Initial Study
Palo Alto High School Master Plan 82 ESA / 209002
Initial Study September 2009
The Police Department handled more than 58,700 calls for service in fiscal year 2007-08,
or about 161 calls per day. The average response time for emergency calls is 4 minutes
32 seconds. Police Department statistics show 127 reported crimes per 1,000 residents,
with 87 reported crimes per officer last year. The Police Department is located at 275
Forest Avenue, approximately one-mile from the Paly campus.
Public Schools
The PAUSD attendance area includes the City of Palo Alto, Stanford University, and
areas of Los Altos Hills, Palo Alto Hills, and Portola Valley. The PAUSD consists of
twelve elementary schools (grades K-5), three middle schools (6-8), and two high schools
(9-12). In addition, the District operates a pre-school, Young Fives program, a self-
supporting Adult School, the Hospital School at Stanford’s Lucille Packard Children’s
Hospital, and summer school. The total District enrollment for the 2008/2009 school year
is 11,431.
Discussion
a.i-ii) Less than Significant. The proposed project would result in construction of new
buildings and other site improvements to accommodate anticipated enrollment
increases through buildout of the Master Plan in 2017. While no off-site access
improvements are proposed, parking and drop-off areas would be reconfigured as
part of the project to improve vehicular, pedestrian, and bicycle circulation and
safety on the campus. The proposed project would be required to comply with all
applicable requirements of the California Fire Code, and be consistent with the
California Building Code regarding life safety issues, including emergency vehicle
access. In addition, during the construction document phase, all plans would be
subject to review and approval by the Division of State Architect for a fire and life-
safety compliance review. In consideration of these factors, the proposed project
would not adversely affect the ability of the Palo Alto Fire and Police Departments
to maintain adequate fire and police protection services, or result in the need for
expanded public services that would result in the need for a new or expanded
facilities.
a.iii) No Impact. There are no elements of the proposed project that would adversely
affect public schools. Consequently, no impact is anticipated.
a.iv) Less than Significant. Refer to Section 14, Recreation, for a discussion of the need
for additional park and recreational facilities, and the potential environmental
impacts associated with the provision of new facilities.
a.v) Less than Significant. The proposed project would not adversely affect any other
public services in the City of Palo Alto.
Initial Study
Palo Alto High School Master Plan 83 ESA / 209002
Initial Study September 2009
Sources
City of Palo Alto, City Auditor, Annual Report on City Government Performance,
Service Efforts and Accomplishments Report FY 2007-2008, Summary, January
2009.
City of Palo Alto, Comprehensive Plan Update, 1996.
City of Palo Alto, Draft and Final Environmental Impact Report, Comprehensive Plan
Update, 1996.
City of Palo Alto, Fire Department, www.cityofpaloalto.org/depts/fir/news, accessed July
22, 2009.
City of Palo Alto, Police Department, www.cityofpaloalto.org/depts/pol/news, accessed
July 22, 2009.
Initial Study
Palo Alto High School Master Plan 84 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
14. Recreation
Would the project:
a) Would the project increase the use of existing
neighborhood and regional parks or other recreational
facilities such that substantial physical deterioration of
the facility would occur or be accelerated?
b) Does the project include recreational facilities or
require the construction or expansion of recreational
facilities which might have an adverse physical effect
on the environment?
Setting
The City of Palo Alto owns and operates 28 neighborhood and district parks totaling
approximately 190 acres. They range in size from one-half to two-acre mini-parks to
“district” parks that serve the entire community and feature playing fields, picnic
grounds, and community centers. Many parks feature specialized facilities such as tennis
courts, basketball courts, skate bowls, community gardens, dog exercise areas, and par
courses. The City also owns and operates several large open space preserves such as
Foothills Park. The Recreation Division provides numerous programs, classes, and
special events. Recreation facilities include community centers, pools (including the new
Gunn High School Aquatic Center), and a teen center. The City also maintains PAUSD
athletic fields and tennis courts at all elementary and middle school sites and manages
public use of those facilities. The City of Palo Alto brokers all city athletic fields, tennis
courts and Palo Alto Unified School District school fields. Park Services also maintains
school athletic fields and tennis courts at all elementary and middle school sites. Parks in
the vicinity of Gunn High School include Bol, Briones, and Terman Parks.
Discussion
a, b) Less than Significant. Implementation of the proposed project over buildout of the
Master Plan in 2017 and associated incremental increase in student population at
the project site would not substantially increase the use of existing neighborhood or
regional parks in the vicinity or cause substantial physical deterioration of those
facilities.
Construction of the new gymnasium is proposed to occur in the area currently
occupied by tennis and basketball courts. Some or all of these facilities would be
temporarily disrupted during construction of the new gym. Approximately 45 other
tennis courts located at other schools and parks throughout the City of Palo Alto
(including four at nearby Terman Park) would be available for use by the public
during the closure of Gunn’s courts. New tennis and basketball courts would be
constructed in areas adjacent to the new gym. Any potential environmental effects
associated with the construction and operation of these recreational facilities are
Initial Study
Palo Alto High School Master Plan 85 ESA / 209002
Initial Study September 2009
discussed in this environmental document and mitigated to a less than significant
level.
Sources
City of Palo Alto, Community Services Department, www.cityofpaloalto.org/depts/csd, accessed July 22, 2009.
City of Palo Alto, Comprehensive Plan Update, 1996.
City of Palo Alto, Draft and Final Environmental Impact Report, Comprehensive Plan
Update, 1996.
Initial Study
Palo Alto High School Master Plan 86 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
15. Transportation/Traffic
Would the project:
a) Cause an increase in traffic which is substantial in
relation to the existing traffic load and capacity of the
street system (i.e., result in a substantial increase in
either the number of vehicle trips, the volume-to-
capacity ratio on roads, or congestion at intersections)?
b) Exceed, either individually or cumulatively, a level of
service standard established by the county congestion
management agency for designated roads or
highways?
c) Result in a change in air traffic patterns, including
either an increase in traffic levels or a change in
location that results in substantial safety risks?
d) Substantially increase hazards due to a design feature
(e.g., sharp curves or dangerous intersections) or
incompatible uses (e.g., farm equipment)?
e) Result in inadequate emergency access?
f) Result in inadequate parking capacity?
g) Conflict with adopted policies, plans, or programs
supporting alternative transportation (e.g., bus
turnouts, bicycle racks)?
Setting
Palo Alto High School is located on the southeast corner of the intersection of El Camino
Real (State Route (SR) 82) and Embarcadero Road. The school has three primary
entrances/exits, one from El Camino Real, one from Embarcadero road, and one from
Churchill Avenue. The three entrances are currently controlled with stops signs on the
driveway approaches.18
The driveway from Embarcadero Road includes left- and right-turn (eastbound and
westbound) ingress from Embarcadero Road, but only right-turn egress to eastbound
Embarcadero Road. This would change with signalization of the driveway, which as
planned, includes left- and right-turn access to and from Embarcadero Road.
Pedestrian and bicycle access from Embarcadero Road is provided with a signal
controlled crosswalk approximately 200 feet easterly of the school driveway. The
crosswalk effectively links the school with the shopping center and areas to the northeast,
and currently accommodates a large volume of both pedestrian and bicycle traffic.
Vehicle traffic currently backs up on Churchill Avenue during the morning peak hour,
particularly in the westbound direction behind the traffic light at El Camino Real. The
18 The driveway at Embarcadero Road, which aligns with the Town and Country Shopping Center, is schedule to be
signalized with the next year as part of the new Trader Joe’s project.
Initial Study
Palo Alto High School Master Plan 87 ESA / 209002
Initial Study September 2009
driveway to Embarcadero Road is congested during student arrival and departure periods.
Vehicle use of the El Camino Real driveway is limited to right-turns in and out.
Existing Traffic Volumes and Intersection Lane Configurations
Five study intersections that would be most affected by project traffic were selected for
analysis:
1. El Camino Real and Embarcadero Road
2. Embarcadero Road and School Driveway
3. El Camino Real and Churchill Avenue
4. Churchill Avenue and Alma Street
5. Churchill Avenue and School Driveway
The study intersections were analyzed during weekday a.m. peak-hour traffic conditions.
Peak traffic conditions, which would coincide with school traffic, typically occur during the
morning commute periods (between 7:00 a.m. and 9:00 a.m.). Intersection operations were
evaluated for the one hour during the morning peak period for which the highest traffic
volumes were measured.
Vehicle counts at the driveways were conducted at the start and end of the school day on
a Friday in March (March 13, 2009). The counts included inbound and outbound
vehicles, as well as count of parked cars by location.
Morning drop-offs and afternoon pick-ups are part of the student commute. A total of 467
drop-offs occurred during the count period. Of these approximately 49 percent (228 drop-
offs) were in front of the Haymarket Theatre, 17 percent (80 drop-offs) were in front of
the tower building, and 34 percent (159 drop-offs) occurred at the end of the driveway
from Churchill Avenue.19 The primary issue during drop-offs in the morning is the
number of vehicles attempting to leave the site during the 20-minute morning peak
through the Embarcadero Road driveway, as there are limited queuing and stacking lanes.
Parking at the high school is currently concentrated in three locations as shown in Figure
12. The school has a total of 555 parking spaces. Lots A, B, C, D, and E, with a total of
295 parking spaces are located in the northwest corner of the school site. Lot F (a
combination of two smaller lots) with 57 parking spaces is located in the northeast
corner. Lots G, H, I, and K, with a total of 203 parking spaces, are located in the southern
portion of the school property with access from Churchill Avenue.
Parking demand at the high school fluctuates very little over the course of the day, but
generally, the lots in close proximity to the campus buildings (Lots A, C, E, F, G, and H)
operate close to capacity, and the more remote lots (lots B, D, I, and K) typically have
parking spaces available. Lot D can have upwards of 100 empty spaces during the day,
while Lot I, near Churchill Avenue, can have 20 to 40 empty parking spaces. As a whole,
19 This does not include students dropped off on side streets or in the Town and Country Shopping Center.
Initial Study
Palo Alto High School Master Plan 88 ESA / 209002
Initial Study September 2009
the high school has a peak parking demand of approximately 416 parking spaces (75
percent).
Palo Alto High School Master Plan . 209002
Figure 12
AM and PM Peak Hour
Intersection Volumes and
Parking Count Summaries
SOURCE: Wilson (2009). Merci. LL
Initial Study
Palo Alto High School Master Plan 90 ESA / 209002
Initial Study September 2009
Existing Intersection Operations
The operations of roadway facilities are described with the term Level of Service. Level
of Service (LOS) is a qualitative description of traffic flow based on such factors as
speed, travel time, delay, and freedom to maneuver. Six levels are defined from LOS A,
as the best operating conditions, to LOS F, or the worst operating conditions. LOS E
represents “at-capacity” operations. When volumes exceed capacity, stop-and-go
conditions result, and operations are designated as LOS F.
Level of Service Calculation Method. The LOS calculation methodology for
intersections is dependent on the type of traffic control device, traffic signals or stop
signs. The LOS methodology used in this analysis bases a signalized intersection’s
operation on the average control delay calculated using methods described in Chapter 16
of the 2000 Highway Capacity Manual (Transportation Research Board, 2000). The
average delay for signalized intersections was calculated using TRAFFIX analysis
software and is correlated to a LOS designation as shown in Table 4. The LOS standard
(i.e., minimum acceptable operations) for the City of Palo Alto is LOS D.
TABLE 4
SIGNALIZED INTERSECTION LEVEL OF SERVICE DEFINITIONS
Level of
Service
Average Control Delay
Per Vehicle
(Seconds) Description
A ≤ 10.0 Operations with very low delay occurring with favorable progression
and/or short cycle length.
B 10.1 to 20.0 Operations with low delay occurring with good progression and/or short
cycle lengths.
C 20.1 to 35.0 Operations with average delays resulting from fair progression and/or
longer cycle lengths. Individual cycle failures begin to appear.
D 35.1 to 55.0
Operations with longer delays due to a combination of unfavorable
progression, long cycle lengths, and high V/C ratios. Many vehicles stop
and individual cycle failures are noticeable.
E 55.1 to 80.0
Operations with high delay values indicating poor progression, long cycle
lengths, and high V/C ratios. Individual cycle failures are frequent
occurrences.
F > 80.0 Operations with delays unacceptable to most drivers occurring due to
over-saturation, poor progression, or very long cycle lengths.
SOURCE: Transportation Research Board, 2000 Highway Capacity Manual.
Intersection LOS calculations were conducted at the unsignalized intersection using the
methodologies for two-way stop-controlled (TWSC) intersections contained in Chapter
17 of the 2000 Highway Capacity Manual (HCM). The LOS rating is based on the
control delay for the stop-controlled movement expressed in seconds per vehicle. Control
delay includes initial deceleration delay, queue move-up time, stopped delay, and final
acceleration delay. Table 5 presents the range of average control delay that corresponds
Initial Study
Palo Alto High School Master Plan 91 ESA / 209002
Initial Study September 2009
to each LOS designation. The control delay was calculated using the TRAFFIX analysis
software.
TABLE 5
LEVEL OF SERVICE CRITERIA FOR UNSIGNALIZED INTERSECTIONS
Level of
Service
Average Control
Delay Per Vehicle
(Seconds) Description
A ≤ 10.0 Little or no delay
B 10.1 to 15.0 Short Traffic delays
C 15.1 to 25.0 Average traffic delays
D 25.1 to 35.0 Long traffic delays
E 35.1 to 50.0 Very long traffic delays
F > 50.0 Extreme traffic delays with intersection capacity exceeded
SOURCE: Transportation Research Board, 2000 Highway Capacity Manual.
Existing Intersection Levels of Service. The existing lane configurations, signal
phasing, and peak-hour turning movement volumes were used to calculate the LOS for
the study intersections. The results of the LOS analysis are presented in Table 6. All of
the study intersections are currently operating at acceptable levels.
TABLE 6
EXISTING INTERSECTION AM PEAK-HOUR LEVELS OF SERVICE (LOS)
ANDAVERAGE VEHICLE DELAY (SECONDS/VEHICLE)a
Existing
Intersection
Control
Typeb Delayc LOS
El Camino Real and Embarcadero Road Signal 43.9 D
Embarcadero Road and School Driveway Signal 9.4 A
El Camino Real and Churchill Avenue Signal 22.8 C
Churchill Avenue and Alma Street Signal 35.0 C
Churchill Avenue and School Driveway TWSC 22.1 C
a LOS calculations performed for using TRAFFIX and the 2000 Highway Capacity Manual operations analysis
methodology.
b TWSC = Two-way stop (sign) controlled
c Represents overall intersection delay for signalized intersections, worst-case controlled movement delay for minor street stop intersection. SOURCE: Wilson (2009).
Pedestrian and Bicycle Facilities
Pedestrian facilities include sidewalks, crosswalks, and pedestrian signals. The existing
school site currently contains pedestrian facilities. School route crosswalks exist on
Embarcadero Road north of the driveway and at the intersection of Churchill and
Castilleja Avenues.
Initial Study
Palo Alto High School Master Plan 92 ESA / 209002
Initial Study September 2009
Bicycle facilities include bike paths, bike lanes, and bike routes. Bike paths are paved
trails that are separated from the roadways. Bike lanes are lanes on roadways that are
designated for use by bicycles by striping, pavement legends, and signs. Bike routes are
roadways that are designated for bicycle use with signs, but no separate lane width.
Within the vicinity of the project site, there are bike lanes on Churchill Avenue between
Bryant Street and El Camino Real. In addition, bicycles are allowed in paved path within
the Caltrain right-of-way.
Bicycle counts were conducted at the start and end of the school day on a Friday in
March (March 13, 2009). The counts included both inbound and outbound bicycles by
location, as well as count of parked bicycles by location.20
Bicycle counts, illustrated in Figure 13, reveal that approximately 410 students bicycle to
school. Approximately 39 percent (161 students) entered from Churchill and Castilleja
Avenues, 32 percent (129 students) from the signalized crossing at Embarcadero Road,
12 percent (50 students) from the intersection of El Camino Real and Embarcadero Road,
and 17 percent (71 students from the northeast corner of the campus at the Caltrain tracks
above Embarcadero Road. Outbound bicycle traffic in the afternoon is more dispersed
over time, as students depart over an extended time period; however, the direction of
departures is more or less the reverse from the morning arrivals.
By comparison, counts conducted by the Parent Teacher Association (PTA) on a warmer
day, have documented upwards of 520 students bicycling to school, roughly 27 percent
more than was counted in March.
Bike cages are generally located at three points in the central area of the campus,
including near the gym, near the science building, and near the student center.
Transit Facilities
Bus service in Santa Clara County is operated by the Santa Clara Valley Transportation
Authority (VTA). Commuter rail service (Caltrain) is provided from San Francisco to
Gilroy by the Peninsula Joint Powers Board.
Route 22 is a local bus route that provides service between the Eastridge neighborhood in
San Jose and Palo Alto/Menlo Park 24 hours a day, seven days a week. It operates on El
Camino Real along the project frontage.
The Embarcadero Shuttle is a free service that operates Monday through Friday. The
shuttle runs every 15 minutes during commute hours and is coordinated with the Caltrain
schedule. It serves employers in the Embarcadero/Baylands area, residents in the
Embarcadero Road corridor and students at Palo Alto High School. It operates on
Embarcadero Road along the project frontage.
20 It should be noted that both vehicle and bicycle counts represent a worst-case scenario as the weather was cold in
March. Mode-shift would occur as weather improves (i.e., more bicycling and walking would occur on a warm
day).
Palo Alto High School Master Plan . 209002
Figure 13
Bicycles and AM/PM Peak Period
Pickup/Dropoff Volumes
SOURCE: Wilson (2009). Merci. LL
Initial Study
Palo Alto High School Master Plan 94 ESA / 209002
Initial Study September 2009
Discussion
a, b) Less than Significant. Implementation of the proposed project over buildout of the
Master Plan in 2017 and associated incremental increase in student population at
the project site would increase trips to the high school. The vehicle trip generation
for the proposed project is presented in Table 7. Vehicle trip generation for the
proposed improvements was estimated based on trip generation rates published in the
Institute of Transportation Engineers Trip Generation (8th edition). The proposed
high school expansion is estimated to generate approximately 138 net new morning
vehicle trips (95 inbound and 43 outbound) at the school driveways.
TABLE 7
AM PEAK HOUR TRIP FORECAST
Existing Student
Population
Forecast 2018
Student Population Net Increase in Tripsa
Net Inbound/
Outbound Trips
1,773 2,291 138 95/43
a Trip generation was based on the trip generation rates published in ITE Trip Generation, 8th edition. SOURCE: Wilson, 2009; ITE, 2008.
The vehicle trip distribution pattern for the proposed project was estimated based on
the existing travel patterns of students and faculty from the traffic counts conducted
in March 2009.
Project Conditions
Project conditions are defined as existing conditions plus traffic added by the
proposed project. Project impacts are then identified by comparing the LOS results
under project conditions to those under existing conditions.
The results of the LOS analysis for project conditions are summarized in Table 8;
turning movement counts and LOS calculations are on-file at the District offices.
With the addition of project-generated traffic, the study intersections would continue
to operate at acceptable levels of service during the a.m. peak hour. Therefore, it is
considered a less than significant impact.
Cumulative Conditions
Cumulative Conditions includes estimated volumes based on forecasts of the Year
2018 baseline traffic volumes. The Year 2018 baseline conditions were developed
using the City of Palo Alto’s traffic forecasts for the years 2010, 2013, and 2015
with a pro rata increase to 2018.
Initial Study
Palo Alto High School Master Plan 95 ESA / 209002
Initial Study September 2009
TABLE 8
EXISTING AND FUTURE LEVELS OF SERVICE (LOS) AND
AVERAGE VEHICLE DEALY (seconds/vehicles)a
Control Existing Project Cumulative w/Project
Intersection Typeb Delayc LOS Delayc LOS Delayc LOS
AM Peak Hour
El Camino Real and Embarcadero Road Signal 43.9 D 43.9 D 48.4 D
Embarcadero Road and School Driveway Signal 9.4 A 9.7 A 10.5 B
El Camino Real and Churchill Avenue Signal 22.8 C 22.9 C 22.8 C
Churchill Avenue and Alma Street Signal 35.0 C 35.9 D 43.0 D
Churchill Avenue and School Driveway TWSC 22.1 C 24.9 C 30.9 D
a LOS calculations performed for using TRAFFIX and the 2000 Highway Capacity Manual operations analysis methodology. b TWSC = Two-way stop (sign) controlled
c Represents overall intersection delay for signalized intersections, worst-case controlled movement delay for minor street stop intersection. SOURCE: Wilson (2009)
Peak-hour levels of service at the study intersections for Cumulative Conditions are
summarized in Table 8. Under Cumulative Conditions, the delay will increase at the
study intersection, but will continue to operate at acceptable levels during the a.m.
peak hour. Therefore, the project’s impact to Cumulative Conditions would be less
than significant.
Construction Period
Construction of the proposed modifications to the school is anticipated to
commence in summer 2010, and would be conducted in phases. Construction
activities that would generate off-site traffic would include the initial delivery of
construction vehicles and equipment to the project site, the daily arrival and
departure of construction workers, and the delivery of materials throughout the
construction period, and removal of construction debris. Deliveries would include
shipments of concrete, lumber, and other building materials for on-site structures,
utilities (e.g., irrigation and plumbing equipment, electrical supplies) and paving
and landscaping materials.
Construction-generated traffic would be temporary, and therefore, would not result
in any long-term degradation in operating conditions on any project roadways. The
impact of construction-related traffic would be a temporary and intermittent
lessening of the capacities of project area streets because of the slower movements
and larger turning radii of construction trucks compared to passenger vehicles.
However, given the proximity of the project site to major arterials (Embarcadero
Road, Churchill Avenue) and to El Camino Real, construction trucks would have
relatively easy and direct routes. Most construction traffic would be dispersed
Initial Study
Palo Alto High School Master Plan 96 ESA / 209002
Initial Study September 2009
throughout the day. Thus, the temporary increase would not significantly disrupt
daily traffic flow on any of the study area roadways.
Although the impact would be less than significant, truck traffic could have some
adverse effect on traffic flow in the study area. As such, the transport of
construction materials and equipment should be limited to off-peak traffic periods.
This measure should be incorporated by the school district into the contract
specifications documents to ensure implementation by the construction
contractor(s).
c) No Impact. The proposed school would not change air traffic patterns, increase air
traffic levels or result in a change in location that would result in substantial safety
risks. There would be no project effect.
d) Less than Significant with Mitigation. The project would result in an increase in
vehicle trips, as well as an increase in pedestrian traffic within the project site and
on local roadways, and correspondingly, would increase the potential for interaction
between these travel modes.
Sidewalks currently exist on roadways adjacent to the project site. To further
improve pedestrian circulation, pedestrian walkways would be enhanced from the
sidewalk and all passenger loading/unloading zones to the main entrance to the
campus site.
Bicycle access to the high school would increase as student population increases.
Assuming the same rate of bicycle use as observed in the March 2009 counts, the
projected number of cyclists at buildout of the Master Plan would be approximately
540. The high school would continue to encourage bicycling to campus as part of
their Transportation Demand Management program, and thus would provide
adequate and secure bicycle parking, in the form of bicycle cages, at convenient and
commute entrances.
Circulation and parking aisles at the high school would continue to serve both one-
way and two-way traffic and provide both angled and perpendicular parking spaces.
The aisles would be designed to be wide enough for maneuvering all types of
passenger vehicles.
Based on the residential distribution of existing students and transit routes, the
school would generate pedestrian traffic through the neighborhood and along
roadways that front the school property. The existing sidewalks on all street
frontages would accommodate the pedestrian traffic.
Implementation of Mitigation Measures TRAN-1 and TRAN-2 would reduce on-
site circulation impacts to less-than-significant levels.
Initial Study
Palo Alto High School Master Plan 97 ESA / 209002
Initial Study September 2009
Mitigation Measure TRAN-1: PAUSD shall incorporate the following
measures into the project site’s final internal circulation design:
• Internal driveway approaches shall be painted red to prohibit stopping and maintain sight-distance;
• Internal roadway curbs shall be painted red to prohibit stopping;
• Internal circulation would use a curbside drop-off zone, which shall be painted white and striped with a lane to allow vehicles to pass on the left-side of loading/unloading vehicles;
• The loading zone shall be marked with signs/pavement markings that make vehicles aware of pedestrian and loading activities;
• Signs and pavement markings (i.e., painted arrows) shall designate directional flow through the parking lot.
Mitigation Measure TRAN-2: PAUSD shall integrate the following
measures to reduce potential queuing impacts:
• Circulate informational flyers to parents and students that discuss on-site circulation patterns and designated parking areas;
• Encourage drivers with disabled passengers that would require longer dwell times (i.e., wheelchair users) to use ADA parking spaces for loading/unload;
• Use staff to monitor and direct on-site traffic during peak drop-off/pick-up times both before and after school (i.e., 7:45 a.m. to 8:00 a.m.).
With implementation of the above mitigation measures, there would be no apparent
circulation design features that would create a traffic safety hazard or significantly
increase the potential for conflicts between vehicles, pedestrians and bicycles.
e) Less than Significant. The proposed project is located at the intersection of major
roadways (El Camino Real and Embarcadero Road). The driveways as designed in
the site plan would provide adequate emergency access. There would be no
blockage of access or traffic pattern disturbance that would significantly affect
emergency access. Red curb will be used along interior roadways and driveways to
provide sufficient response time for emergency vehicles. The fire lane must be a
minimum of 18 feet in width and must be kept clear at all times. The project’s
effect would be less than significant.
f) Less than Significant. The City of Palo Alto requires one parking space for every
five students, plus one space for each four teaching stations. The proposed daily
population for the high school is approximately 2,300 students and 92 teachers (1
for every 25 students), thus requiring 483 parking spaces. Using the current parking
demand of approximately 416 spaces on a typical weekday, the future demand rate
Initial Study
Palo Alto High School Master Plan 98 ESA / 209002
Initial Study September 2009
with buildout of the Master Plan would be approximately 550 spaces. The proposed
on-site parking supply for the school is proposed to remain at 555 spaces; the
project’s effect would be less than significant.
The high school has an existing parking demand management program which limits
student driving to campus though permits. The program is enforced through
cooperation with the City police, which uses parking enforcement (tickets) to
ensure adherence to the program.
g) Less than Significant. The project is located in an established urban area, and
buildout of the Master Plan would not conflict with adopted policies, plans, or
programs supporting alternative transportation.
The increase in students and employees could increase the use of alternative
transportation modes. The high school has, and will continue to implement, a
Transportation Demand Management (TDM) program that shifts students to
alternative modes of travel. Decreasing the volume of vehicular traffic to the school
through the promotion of alternative modes of travel including carpooling, biking,
or use of public transit, is fundamental to any TDM program. The project’s effect
would be less than significant.
Sources
Institute of Transportation Engineers, Trip Generation (8th edition), 2008.
Santa Clara Valley Transportation Authority (VTA), Transit and Rail Map, http://www.vta.org/schedules/pdf/bus_rail_map_a.pdf, accessed August 18, 2009.
Santa Clara Valley Transportation Authority (VTA), Bike Map, http://www.vta.org/schedules/pdf/vta_bike_map_a.pdf, accessed August 18, 2009.
Transportation Research Board, Highway Capacity Manual, 2000.
Wilson Engineering, On-Site Traffic Study for Gunn High School. Prepared for the Palo Alto Unified School District, May 2009.
Wilson Engineering. An Assessment of Gunn and Play High Schools Trip Generation, Traffic Assignment and LOS Assessment Associated with Measure B, prepared for the Palo Alto Unified School District, August 7, 2009.
Initial Study
Palo Alto High School Master Plan 99 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
16. Utilities and Service Systems
Would the project:
a) Exceed wastewater treatment requirements of the
applicable Regional Water Quality Control Board?
b) Require or result in the construction of new water or
wastewater treatment facilities or expansion of
existing facilities, the construction of which could
cause significant environmental effects?
c) Require or result in the construction of new storm
water drainage facilities or expansion of existing
facilities, the construction of which could cause
significant environmental effects?
d) Have sufficient water supplies available to serve the
project from existing entitlements and resources, or
are new or expanded entitlements needed?
e) Result in a determination by the wastewater treatment
provider which serves or may serve the project that it
has adequate capacity to serve the project’s projected
demand in addition to the provider’s existing
commitments?
f) Be served by a landfill with sufficient permitted
capacity to accommodate the project’s solid waste
disposal needs?
g) Comply with federal, state, and local statutes and
regulations related to solid waste?
Setting
Water supply to the City of Palo Alto is provided by the City Utilities Department through
purchases from the San Francisco Public Utilities Commission’s Hetch Hetchy water supply
system. On average, 85 percent of this water is derived from snow melt flowing into the
Hetch Hetchy Reservoir in Yosemite National Park, and the balance is from runoff stored
in San Francisco Bay Area reservoirs on the Peninsula and in the East Bay. There are five
wells in Palo Alto that are maintained as an emergency source of supply. Palo Alto also
uses recycled water from the Regional Water Quality Control Plant (RWQCP) to irrigate
the municipal golf course, Greer Park, and landscaping around the RWQCP.
The City owns and operates an approximate 200-mile wastewater collection system and
operates the Regional Water Quality Control Plant (RWQCP). The RWQCP also serves
Mountain View, Los Altos, Los Altos Hills, East Palo Alto, and Stanford University.
Approximately 26 million gallons of wastewater are processed on a daily basis at the
RWQCP and 9.5 billion gallons annually (3.3 billion gallons from Palo Alto).
The City also provides weekly waste, yard waste and recycling collection service to all
homes and businesses in the City. Yard waste is currently composted at the Palo Alto
Landfill. Waste collected at the curbside goes to the Sunnyvale Materials Recovery and
Transfer Station or to another facility for additional sorting. The processed waste is
Initial Study
Palo Alto High School Master Plan 100 ESA / 209002
Initial Study September 2009
ultimately placed in a landfill at the Kirby Canyon Landfill in San Jose. The Palo Alto
Landfill, which is scheduled to close in 2011, currently accepts waste from self-haul and
City vehicles. The City is required by State law to divert 50 percent of its waste stream
from landfills. In 2006, the City diverted 62 percent of its waste stream.
Discussion
a, e) Less than Significant. Minimal growth in student and staff populations would
occur over the duration of the Master Plan. As discussed in the Project Description,
the proposed Master Plan identifies an increase in the student enrollment at the high
school through 2017. The student capacity over the eight-year period of the Master
Plan would increase by approximately 350 students, or about 44 students per year.
This increase would not result in substantial increases in wastewater generation
over existing conditions at the project site such that the wastewater treatment
requirements would be exceeded.
Furthermore, the City of Palo Alto’s General Plan EIR found that overall population
growth that would occur in the City (of which future PAUSD students and staff
would be a part) would not create significant amounts of wastewater that would
exceed the RWQCP treatment capacity or require expansion of the treatment plant.
Therefore, the proposed project would result in a less than significant impact
regarding wastewater treatment requirements.
b, d) Less than Significant. The proposed project would result in the development of a
combined maximum total of approximately 110,000-square feet of new educational
uses on the project site. These new uses (e.g., new classrooms, gymnasium, labs,
etc.), and the minor increases in student and staff population they would
accommodate over the Master Plan’s eight-year planning period would
incrementally increase local water demand and wastewater generation at the project
site, as discussed above.
As noted in the General Plan EIR, the City would have access to adequate water
supplies and wastewater treatment capacity to serve anticipated population growth.
Therefore, the proposed project would not require new or expanded water or
wastewater facilities and effects to water treatment facilities would be less than
significant.
c) Less than Significant. New buildings and other structures proposed under the
Master Plan would require connection to the existing on-site stormwater drainage
system. Stormwater runoff from the project site would be routed to the municipal
stormwater collection system.
As discussed in Section 8, Hydrology and Water Quality, and as required by
Mitigation Measure HYD-1, the PAUSD would be required to develop a Storm
Water Pollution Prevention Plan that would identify Best Management Practices to
Initial Study
Palo Alto High School Master Plan 101 ESA / 209002
Initial Study September 2009
ensure that construction of new on-site stormwater infrastructure would not result in
adverse impacts to water quality.
f, g) Less than Significant. Palo Alto High School student and staff population growth
would be relatively stable over the eight-year Master Plan horizon. The Kirby
Canyon Landfill has adequate capacity until 2022, and as such, the General Plan’s
regional growth, including minor increases in local student and staff populations at
the project site, would not adversely affect capacity at the Kirby Canyon Landfill;
therefore, impacts to solid waste would be less than significant.
Additionally, in conformance with Mitigation Measure HAZ-1, the proposed
project would not affect compliance with solid waste statutes and regulations.
Sources
California Integrated Waste Management Board (CIWMB), Active Landfills Profile for Kirby Canyon Recycling and Disposal Facility, www.ciwmb.ca.gov/profiles/facility/landfill, accessed July 23, 2009.
CIWMB, Jurisdiction Profile for City of Palo Alto, www.ciwmb.ca.gov/profiles/Juris, accessed July 23, 2009.
City of Palo Alto, All About Your Utilities: Palo Alto’s Homegrown Asset, April 10, 2007.
City of Palo Alto, Comprehensive Plan Update, 1996.
City of Palo Alto, Draft and Final Environmental Impact Report, Comprehensive Plan Update, 1996.
Initial Study
Palo Alto High School Master Plan 102 ESA / 209002
Initial Study September 2009
Issues (and Supporting Information Sources):
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporation
Less Than
Significant
Impact No Impact
17. Mandatory Findings of Significance Would the project:
a) Does the project have the potential to degrade the quality of the environment, substantially reduce the habitat of a fish or wildlife species, cause a fish or wildlife population to drop below self-sustaining levels, threaten to eliminate a plant or animal community, reduce the number or restrict the range of a rare or endangered plant or animal or eliminate important examples of the major periods of California history or prehistory?
b) Does the project have impacts that are individually limited, but cumulative considerable? (“Cumulative considerable” means that the incremental effects of a project are considerable when viewed in connection with the effects of past projects, the effects of other current projects, and the effects of probable future projects)?
c) Does the project have environmental effects which will cause substantial adverse effects on human beings, either directly or indirectly?
Discussion
a) Less Than Significant with Mitigation. Based upon background research, site
reconnaissance, and the project description, the project does not have the potential
to substantially reduce the habitat of a fish or wildlife species, cause a fish or
wildlife population to drop below self-sustaining levels, threaten to eliminate a
plant or animal community, or reduce the number or restrict the range of a rare or
endangered plant or animal. The proposed project could have an adverse impact on
the historic significance of the Haymarket Theater or Tower Building. However,
Mitigation Measure CUL-1 would reduce impacts to less than significant levels.
Any potential short-term increases in potential effects to the environment during
construction are mitigated to a less than significant level, as described throughout
the Initial Study.
b) Less Than Significant with Mitigation. In accordance with CEQA Guidelines
Section 15183, the environmental analysis in this Initial Study was conducted to
determine if there were any project-specific effects that are peculiar to the project or
its site. No project-specific significant effects peculiar to the project or its site were
identified that could not be mitigated to a less than significant level. The proposed
project would contribute to environmental effects in the areas of biological
resources (e.g., loss of trees), temporary increases in construction-generated dust
and noise, temporary increase in sedimentation and water quality effects during
construction, and operational traffic and circulation impacts. Mitigation measures
incorporated herein mitigate any potential contribution to cumulative impacts
associated with these environmental issues. Therefore, the proposed project does
not have impacts that are individually limited, but cumulatively considerable.
Initial Study
Palo Alto High School Master Plan 103 ESA / 209002
Initial Study September 2009
c) Less Than Significant with Mitigation. The project may have significant adverse
effects on human beings in the areas of air quality, noise, and traffic during
construction, and with geologic/seismic considerations with new development.
Mitigation measures AIR-1 and 2; GEO-1; NOI-1 through 4; and TRANS-1 and 2